{"_buckets": {"deposit": "5d436d06-23f9-46ba-ba43-aadf900c7d07"}, "_deposit": {"created_by": 1, "id": "55596", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "55596"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00055596", "sets": ["7"]}, "author_link": ["568839", "568832", "568840", "568838", "568835", "568834", "568831", "568833", "568837", "568836"], "item_10004_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-205", "bibliographicPageEnd": "47", "bibliographicPageStart": "43", "bibliographicVolumeNumber": "2007", "bibliographic_titles": [{"bibliographic_title": "放射線医学総合研究所技術報告書"}]}]}, "item_10004_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "旧X線管から新規X線管に交換したことにより、照射台に掲示している旧X線管での線量率・照射野は参考にすることはできなくなった。同じ規格のX線管でもハンドメイドのため個体差が出てくるからである。今回は新規X線管での線量測定を行い、照射野を決定したので報告する。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "三井, 大輔"}], "nameIdentifiers": [{"nameIdentifier": "568831", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "568832", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "磯, 浩之"}], "nameIdentifiers": [{"nameIdentifier": "568833", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋, 徳啓"}], "nameIdentifiers": [{"nameIdentifier": "568834", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "568835", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三井 大輔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568836", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568837", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "磯 浩之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568838", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "酢屋 徳啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568839", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "568840", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X線棟第3照射室のX線発生装置PANTAK HF-320型X線管交換に伴う照射野の調整と線量測定結果", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X線棟第3照射室のX線発生装置PANTAK HF-320型X線管交換に伴う照射野の調整と線量測定結果"}]}, "item_type_id": "10004", "owner": "1", "path": ["7"], "permalink_uri": "https://repo.qst.go.jp/records/55596", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-01-08"}, "publish_date": "2008-01-08", "publish_status": "0", "recid": "55596", "relation": {}, "relation_version_is_last": true, "title": ["X線棟第3照射室のX線発生装置PANTAK HF-320型X線管交換に伴う照射野の調整と線量測定結果"], "weko_shared_id": -1}
X線棟第3照射室のX線発生装置PANTAK HF-320型X線管交換に伴う照射野の調整と線量測定結果
https://repo.qst.go.jp/records/55596
https://repo.qst.go.jp/records/55596d80afcbf-077d-4890-bc73-4d99140f85ae
Item type | 一般雑誌記事 / Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-01-08 | |||||
タイトル | ||||||
タイトル | X線棟第3照射室のX線発生装置PANTAK HF-320型X線管交換に伴う照射野の調整と線量測定結果 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
三井, 大輔
× 三井, 大輔× 石川, 剛弘× 磯, 浩之× 酢屋, 徳啓× 今関, 等× 三井 大輔× 石川 剛弘× 磯 浩之× 酢屋 徳啓× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 旧X線管から新規X線管に交換したことにより、照射台に掲示している旧X線管での線量率・照射野は参考にすることはできなくなった。同じ規格のX線管でもハンドメイドのため個体差が出てくるからである。今回は新規X線管での線量測定を行い、照射野を決定したので報告する。 | |||||
書誌情報 |