WEKO3
アイテム
COMPLETION OF DC 1 MV POWER SUPPLY SYSTEM FOR ITER NEUTRAL BEAM TEST FACILITY
https://repo.qst.go.jp/records/54929
https://repo.qst.go.jp/records/54929fadab4d4-d925-42ff-abb0-047fd9eb117e
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-11-07 | |||||
タイトル | ||||||
タイトル | COMPLETION OF DC 1 MV POWER SUPPLY SYSTEM FOR ITER NEUTRAL BEAM TEST FACILITY | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tobari, Hiroyuki
× Tobari, Hiroyuki× Kashiwagi, Mieko× Watanabe, Kazuhiro× Maejima, Tetsuya× Yamashita, Yasuo× Dairaku, Masayuki× Oda, Yuki× Sasaki, Shunichi× Kojima, Atsushi× Umeda, Naotaka× Yamanaka, Haruhiko× Shibata, Naoki× Oohara, Shinya× Suto, Tetsuya× Kawakami, Hiroyuki× 戸張 博之× 柏木 美恵子× 渡邊 和弘× 前島 哲也× 大楽 正幸× 佐々木 駿一× 小島 有志× 梅田 尚孝× 山中 晴彦× 柴田 直樹 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to realize the DC 1 MV power supply system for ITER neutral beam injector (NBI) and NB test facility (NBTF), insulation technologies in oil, gas, vacuum and with water have been developed. To supply cooling water and high-temperature water, mechanical and electrical properties of fiber reinforce plastic (FRP) with water absorption was clarified. The mock-up of FRP tube was fabricated and pressure tightness and voltage capability was confirmed. As for high-temperature water supply to the plasma grid, the water resistivity up to 180 oC was experimentally measured and the high-temperature water channel was successfully designed. Based on those developments, manufacturing and installation for the power supply components for the NBTF/MITICA has been progressed and completed. Finally, to verify the voltage holding capability of the DC 1 MV power supply component, high-voltage test has been started by filling SF6 gas inside the components. That was the first high-voltage test in the NBTF/MITICA power supply under the assembled configuration with all components procured by Japan. As an initial test, high-voltage of DC 1.2 MV was applied on the DC generators and DC filter. As a result, stable voltage holding without breakdown for 1 hour was successfully confirmed. | |||||