ENDF/B-VIIIb2 benchmark test with shielding experiments at QST/TIARA

https://repo.qst.go.jp/records/54884
https://repo.qst.go.jp/records/54884
7957fbbc-31b5-4f0a-ba62-9e21adc4e079
Item type 会議発表論文 / Conference Paper(1)
公開日 2018-04-15
タイトル
タイトル ENDF/B-VIIIb2 benchmark test with shielding experiments at QST/TIARA
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 権, セロム

× 権, セロム

WEKO 561215

権, セロム

Search repository
今野, 力

× 今野, 力

WEKO 561216

今野, 力

Search repository
太田, 雅之

× 太田, 雅之

WEKO 561217

太田, 雅之

Search repository
佐藤, 聡

× 佐藤, 聡

WEKO 561218

佐藤, 聡

Search repository
落合, 謙太郎

× 落合, 謙太郎

WEKO 561219

落合, 謙太郎

Search repository
権 セロム

× 権 セロム

WEKO 561220

en 権 セロム

Search repository
太田 雅之

× 太田 雅之

WEKO 561221

en 太田 雅之

Search repository
佐藤 聡

× 佐藤 聡

WEKO 561222

en 佐藤 聡

Search repository
落合 謙太郎

× 落合 謙太郎

WEKO 561223

en 落合 謙太郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Previously we benchmarked the iron and concrete shielding experiments with 40 and 65 MeV neutron sources at QST/TIARA by using ENDF/B-VII.1, FENDL-3.0 and JENDL-4.0/HE. We pointed out that the calculated results with ENDF/B-VII.1 excessively overestimated the measured neutron fluxes more in the thicker test shields in both of the experiments. It was confirmed that the overestimations were due to elastic and non-elastic scattering data of 56Fe and 16O in ENDF/B-VII.1. Several beta versions of ENDF/B-VIII were released in 2016. We analyze the same experiments with ENDF/B-VIIIb2 (2nd beta version which was released in August, 2016) to investigate whether the 56Fe and 16O data in ENDF/B-VIIIb2 are improved. In the iron experiment, the excessive overestimation in the calculated result with ENDF/B-VII.1 decreases in that with ENDF/B-VIIIb2, due to the revision of the elastic and non-elastic scattering cross section data of 56Fe in ENDF/B-VIIIb2. However, the excessive overestimation in the calculated results with ENDF/B-VII.1 does not change in that with ENDF/B-VIIIb2 in the concrete experiment because the 16O data above 20 MeV are not revised in ENDF/B-VIIIb2. The final version of ENDF/B-VIII should be modified based on these results.
書誌情報 Proceedings of the 2016 Annual Symposium on Nuclear Data (NDS 2016) (JAEA-Conf 2017-001)

巻 2017, 号 001, p. 123-128, 発行日 2018-01
出版者
出版者 Japan Atomic Energy Agency
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:55:40.378315
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3