ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Alkaline Durable Anion-Conducting Electrolyte Membranes Prepared by Radiation Induced Grafting of 2-Methyl-4-vinylimidazole for Non-Platinum Direct Hydrazine Hydrate Fuel Cells

https://repo.qst.go.jp/records/54883
https://repo.qst.go.jp/records/54883
bd8aedc1-9769-4966-bf1d-dd8f7cd4e4dc
Item type 会議発表論文 / Conference Paper(1)
公開日 2018-04-15
タイトル
タイトル Alkaline Durable Anion-Conducting Electrolyte Membranes Prepared by Radiation Induced Grafting of 2-Methyl-4-vinylimidazole for Non-Platinum Direct Hydrazine Hydrate Fuel Cells
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 前川, 康成

× 前川, 康成

WEKO 561201

前川, 康成

Search repository
吉村, 公男

× 吉村, 公男

WEKO 561202

吉村, 公男

Search repository
竹内, 航太

× 竹内, 航太

WEKO 561203

竹内, 航太

Search repository
廣木, 章博

× 廣木, 章博

WEKO 561204

廣木, 章博

Search repository
渡邊, 俊

× 渡邊, 俊

WEKO 561205

渡邊, 俊

Search repository
萩原, 時男

× 萩原, 時男

WEKO 561206

萩原, 時男

Search repository
猪谷, 秀幸

× 猪谷, 秀幸

WEKO 561207

猪谷, 秀幸

Search repository
山口, 進

× 山口, 進

WEKO 561208

山口, 進

Search repository
田中, 裕久

× 田中, 裕久

WEKO 561209

田中, 裕久

Search repository
前川 康成

× 前川 康成

WEKO 561210

en 前川 康成

Search repository
吉村 公男

× 吉村 公男

WEKO 561211

en 吉村 公男

Search repository
竹内 航太

× 竹内 航太

WEKO 561212

en 竹内 航太

Search repository
廣木 章博

× 廣木 章博

WEKO 561213

en 廣木 章博

Search repository
猪谷 秀幸

× 猪谷 秀幸

WEKO 561214

en 猪谷 秀幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 For Pt-free alkaline-type fuel cells, anion-conducting polymer electrolyte membranes (AEMs) having a weak base imidazolium group, which scarcely damages the polymer backbones, have been developed. To prevent ring opening hydrolysis and β-elimination reactions, which are the main degradation routes, we conducted the radiation-induced grafting of 2-methyl-4(5)-vinylimidazole (2Me4VIm), which possesses methyl protecting group at imidazole C2 position and no b-protons, with styrene into a poly(ethylene-cotetrafluoro-ethylene) (ETFE) film and subsequent N-alkylation and
ion exchange reactions to obtain 2Me4VIm/St-AEM (Im/St = 75/25) with ion exchange capacity of 1.35 mmol g-1. The conductivity and water uptake are 157 mS cm-1 and 86%, respectively. In 1 M KOH at 80°C, the initial rapid decrease of conductivity was clearly suppressed; then, the membrane maintained the conductivity above 15 mS/cm until 600 h. The semi-logarithmic plots of conductivity show 1st order kinetics, indicating the no b-elimination but only slow ring-opening hydrolysis in the alkaline condition.
書誌情報 ECS Transactions

巻 80, 号 8, p. 979-987, 発行日 2017-09
出版者
出版者 The Electrochemical Society
DOI
識別子タイプ DOI
関連識別子 10.1149/08008.0979ecst
関連サイト
識別子タイプ URI
関連識別子 http://ecst.ecsdl.org/content/80/8/979.abstract
関連名称 http://ecst.ecsdl.org/content/80/8/979.abstract
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:55:41.154909
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3