ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

An individual calibration system for electrometer and ionization chamber of radiotherapy dosimeters

https://repo.qst.go.jp/records/54871
https://repo.qst.go.jp/records/54871
f0c43c57-37cb-4e46-bca2-280bdb8d02d1
Item type 会議発表論文 / Conference Paper(1)
公開日 2018-03-22
タイトル
タイトル An individual calibration system for electrometer and ionization chamber of radiotherapy dosimeters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takase, Nobuharu

× Takase, Nobuharu

WEKO 561098

Takase, Nobuharu

Search repository
Sakata, Suoh

× Sakata, Suoh

WEKO 561099

Sakata, Suoh

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 561100

Endo, Masahiro

Search repository
Narita, Katuhisa

× Narita, Katuhisa

WEKO 561101

Narita, Katuhisa

Search repository
Yamasita, Wataru

× Yamasita, Wataru

WEKO 561102

Yamasita, Wataru

Search repository
Hoteida, Masahiro

× Hoteida, Masahiro

WEKO 561103

Hoteida, Masahiro

Search repository
Sasaki, Yosuke

× Sasaki, Yosuke

WEKO 561104

Sasaki, Yosuke

Search repository
Okuyama, Hiroaki

× Okuyama, Hiroaki

WEKO 561105

Okuyama, Hiroaki

Search repository
Ushiroda, Tota

× Ushiroda, Tota

WEKO 561106

Ushiroda, Tota

Search repository
Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 561107

Mizuno, Hideyuki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 561108

Fukumura, Akifumi

Search repository
佐方 周防

× 佐方 周防

WEKO 561109

en 佐方 周防

Search repository
水野 秀之

× 水野 秀之

WEKO 561110

en 水野 秀之

Search repository
福村 明史

× 福村 明史

WEKO 561111

en 福村 明史

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Since 2004, Association for Nuclear Technology in Medicine (ANTM) has been carrying out a calibration service for radiotherapy dosimeters, as the unique secondary standard dosimeter laboratory in Japanese external radiotherapy field. The service provides an absorbed dose to water calibration factor to a set of chamber and electrometer, at a single electrometer range.
Recently, the authors have established a charge calibration system for electrometer to provide calibration factor at each electrometer range. The new system allows chamber calibration without customer's own electrometers.
Method: We assembled a reference standard measurement device of charge with capacitors and a DC voltmeter. Those are traceable to the corresponding national measurement standard. A customer’s reference class chamber can be calibrated with the best relative expanded uncertainty of 1% (k=2) with the new system.
Result: We compared the results of electrometer with the calibration factors given in the ADCL’s certificate with A2LA accredited symbol. The calibration factors obtained be the authors and ADCL agreed within the relative expanded uncertainties. The results of ionization chambers also were compared with the calibration factors given in the NMIJ test report. Both factors agreed within relative expanded uncertainties.
Conclusion: New calibration system established by the authors has been verified by the two experiments. The individual calibration system for electrometer and chamber would simplify the quality control method of reference dosimeters at radiotherapy facilities.
書誌情報 Japanese Journal Medical Physics

巻 37, 号 Sup.3, p. 167, 発行日 2018-03
出版者
出版者 株式会社国際文献社(一般社団法人日本医学物理学会)
ISSN
収録物識別子タイプ ISSN
収録物識別子 1345-5362
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:55:49.931391
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3