ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

External dose audits of high-energy radiotherapy photon beams in Japan

https://repo.qst.go.jp/records/54730
https://repo.qst.go.jp/records/54730
26d0e167-ddf2-43de-a497-faf9ab12cd02
Item type 会議発表論文 / Conference Paper(1)
公開日 2017-03-22
タイトル
タイトル External dose audits of high-energy radiotherapy photon beams in Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 佐方, 周防

× 佐方, 周防

WEKO 559510

佐方, 周防

Search repository
fukumura, Akifumi

× fukumura, Akifumi

WEKO 559511

fukumura, Akifumi

Search repository
Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 559512

Mizuno, Hideyuki

Search repository
Yamashita, Wataru

× Yamashita, Wataru

WEKO 559513

Yamashita, Wataru

Search repository
Takase, Nobuhiro

× Takase, Nobuhiro

WEKO 559514

Takase, Nobuhiro

Search repository
Hoteida, Masahiro

× Hoteida, Masahiro

WEKO 559515

Hoteida, Masahiro

Search repository
Sasaki, Yosuke

× Sasaki, Yosuke

WEKO 559516

Sasaki, Yosuke

Search repository
Okumura, Hiroaki

× Okumura, Hiroaki

WEKO 559517

Okumura, Hiroaki

Search repository
Usiroda, Tota

× Usiroda, Tota

WEKO 559518

Usiroda, Tota

Search repository
Narita, Katuhisa

× Narita, Katuhisa

WEKO 559519

Narita, Katuhisa

Search repository
佐方 周防

× 佐方 周防

WEKO 559520

en 佐方 周防

Search repository
福村 明史

× 福村 明史

WEKO 559521

en 福村 明史

Search repository
水野 秀之

× 水野 秀之

WEKO 559522

en 水野 秀之

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Nine years has passed since the Association for Nuclear Technology in Medicine (ANTM) launched the external dose quality audit (EDQA) of high energy radiotherapy photon beams for radiotherapy departments in Japan. When EDQA was started, the object was limited to beams of reference condition (10cm square field size, 10cm depth in water) and was expanded to non-reference conditions of field size change and wedge filter insertion in 2010. In this study we report the results of this EDQA and the present status of dose estimation in Japan evaluated from EDQA.
Method: In the EDQA by ANTM, radiophotoluminescent glass dosimeter (RGD) is used as the detector. ANTM send RGD elements and solid phantom to radiotherapy departments and RGD are returned to ANTM after the irradiation of a specified dose. The dose delivered to RGD is measured at Dose Calibration Center of ANTM and is compared to the dose stated by radiotherapy department.
Results: Until March 2016, 3,351 beams of 784 therapy units from 629 departments have been audited. The numbers of beams are classified into 1,663 of reference condition, 1,103 of non-reference field size and 585 wedge filter insertion. The averages of difference between measured and stated dose were 0.37% in reference condition, 0.15% in field change and 0.26% in wedge filter insertion. The standard deviations were around 1% for all conditions.
Conclusion: The external dose QA by ANTM shows that the status of dosimetry at radiotherapy departments in Japan is in satisfying level.
書誌情報 Medical Phyusics International Journal,

巻 4, 号 2, p. 320, 発行日 2016-12
出版者
出版者 International Organization for Medical Physics
ISSN
収録物識別子タイプ ISSN
収録物識別子 2306-4619
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:57:27.206023
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3