Beam Alignment Procedure for Scanned Ion-Beam Therapy

https://repo.qst.go.jp/records/54623
https://repo.qst.go.jp/records/54623
b01e0ead-34ca-4cd2-b4be-95d01e30076c
Item type 会議発表論文 / Conference Paper(1)
公開日 2016-01-14
タイトル
タイトル Beam Alignment Procedure for Scanned Ion-Beam Therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Saraya, Yuichi

× Saraya, Yuichi

WEKO 558065

Saraya, Yuichi

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 558066

Furukawa, Takuji

Search repository
Hara, Yousuke

× Hara, Yousuke

WEKO 558067

Hara, Yousuke

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 558068

Mizushima, Kota

Search repository
Noda, Koji

× Noda, Koji

WEKO 558069

Noda, Koji

Search repository
Saotome, Naoya

× Saotome, Naoya

WEKO 558070

Saotome, Naoya

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 558071

Shirai, Toshiyuki

Search repository
Tansho, Ryohei

× Tansho, Ryohei

WEKO 558072

Tansho, Ryohei

Search repository
Takeshita, Eri

× Takeshita, Eri

WEKO 558073

Takeshita, Eri

Search repository
皿谷 有一

× 皿谷 有一

WEKO 558074

en 皿谷 有一

Search repository
古川 卓司

× 古川 卓司

WEKO 558075

en 古川 卓司

Search repository
原 洋介

× 原 洋介

WEKO 558076

en 原 洋介

Search repository
水島 康太

× 水島 康太

WEKO 558077

en 水島 康太

Search repository
野田 耕司

× 野田 耕司

WEKO 558078

en 野田 耕司

Search repository
早乙女 直也

× 早乙女 直也

WEKO 558079

en 早乙女 直也

Search repository
白井 敏之

× 白井 敏之

WEKO 558080

en 白井 敏之

Search repository
丹正 亮平

× 丹正 亮平

WEKO 558081

en 丹正 亮平

Search repository
竹下 英里

× 竹下 英里

WEKO 558082

en 竹下 英里

Search repository
抄録
内容記述タイプ Abstract
内容記述 It's important to control the beam position for the 3D pencil-beam scanning because the position accuracy of the beam has a serious matter on the alignment of the irradiation field. In order to suppress this matter, we have been developed a simple procedure for the beam tuning. The fluctuation of the beam position is tuned with the steering magnets (ST) and the fluorescent screen monitors (SCN). At first, the beam positions are measured by two SCN and the kick angles of two ST are calculated using deviates from the center of the beam position measured by SCN and the transfer matrix. After the tuning, the beam position at the isocenter is checked on the verification system for the alignment of the beam consists of the SCN and the iron sphere phantom. If the beam position is deviated from the center, one of ST placed on most downstream of the beam transport line will be corrected. These adjustments are iterated until the deviation for all energies of the beam are within 0.5 mm. We have been performed the beam commissioning using our procedure in Kanagawa Cancer Center. In this presentation, we will report on the result of these measurements.
書誌情報 HIAT2015 - Proceedings

発行日 2015-09
関連サイト
識別子タイプ URI
関連識別子 http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm
関連名称 http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:58:45.871871
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3