Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy

https://repo.qst.go.jp/records/54620
https://repo.qst.go.jp/records/54620
ab8abd1d-31c3-4b30-9f47-d8125dd0b488
Item type 会議発表論文 / Conference Paper(1)
公開日 2016-01-14
タイトル
タイトル Development of Electron Cyclotron Resonance Ion Sources for Carbon-Ion Radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Muramatsu, Masayuki

× Muramatsu, Masayuki

WEKO 558025

Muramatsu, Masayuki

Search repository
Anne, Drentje

× Anne, Drentje

WEKO 558026

Anne, Drentje

Search repository
Kitagawa, Atsushi

× Kitagawa, Atsushi

WEKO 558027

Kitagawa, Atsushi

Search repository
村松 正幸

× 村松 正幸

WEKO 558028

en 村松 正幸

Search repository
アルネ ドレンチェ

× アルネ ドレンチェ

WEKO 558029

en アルネ ドレンチェ

Search repository
北川 敦志

× 北川 敦志

WEKO 558030

en 北川 敦志

Search repository
抄録
内容記述タイプ Abstract
内容記述 Compact ECR ion sources have been developed for high energy carbon-ion radiotherapy (C-ion RT). Three compact ECR ion sources have been developed as the prototype at NIRS. The first ion source was used the microwave of 2.45 GHz to reduce the construction cost of the source as much as possible. This ion source could not obtain enough intensity of C2+ because there were problems in microwave injection and beam extraction system. The second and third ion sources, named Kei and Kei2, solved these problems. The structure of Kei and Kei2 were similar, however Kei2 improved on the magnetic field configuration. The beam intensity of 0.26 mA and 0.78 mA for C4+ were obtained by Kei and by Kei2, respectively. All of later C-ion RT facilities in Japan, the Gunma University Heavy Ion Medical Center, the Saga Heavy Ion Medical Accelerator in Tosu, and the Ion-beam Radiation Oncology Center in Kanagawa, installed copies of Kei2 and named them KeiGM, KeiSA, and KeiGM3. On the other hand, the original Kei2 have been installed in the HIMAC at NIRS and produces carbon beams for experimental use. Developments and some improvements of these Kei-series ECR ion sources will be reported.
書誌情報 HIAT2015 - Proceedings

発行日 2015-09
関連サイト
識別子タイプ URI
関連識別子 http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm
関連名称 http://www.rarf.riken.jp/hiat2015/proceedings/html/inst.htm
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:58:47.955999
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3