WEKO3
アイテム
MAGNETIC-FIELD MEASUREMENTS OF SUPERCONDUCTING MAGNETS FOR A HEAVY-ION ROTATING-GANTRY AND BEAMTRACKING SIMULATIONS
https://repo.qst.go.jp/records/54572
https://repo.qst.go.jp/records/54572e6946b5b-b873-4350-9966-5a606701e4c4
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-07-21 | |||||
タイトル | ||||||
タイトル | MAGNETIC-FIELD MEASUREMENTS OF SUPERCONDUCTING MAGNETS FOR A HEAVY-ION ROTATING-GANTRY AND BEAMTRACKING SIMULATIONS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Suzuki, Shinji
× Suzuki, Shinji× Iwata, Yoshiyuki× Noda, Koji× Shirai, Toshiyuki× Furukawa, Takuji× Fujita, Takashi× Shouda, Kouichi× Mori, Shinichiro× Mizushima, Kota× Hara, Yousuke× al., et× 鈴木 伸司× 岩田 佳之× 野田 耕司× 白井 敏之× 古川 卓司× 藤田 敬× 正田 光一× 森 慎一郎× 水島 康太× 原 洋介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Manufacture of superconducting rotating-gantry for heavy-ion radiotherapy is currently in progress. This rotating gantry can transport heavy ions having 430 MeV/nucleon to an isocenter with irradiation angles of over 0-360 degrees, and enables advanced radiationtherapy. To reduce the size and weight of the rotating gantry, we designed superconducting magnets that can independently excite dipole and quadrupole field. The three-dimensional scanning-irradiation method is performed in this rotating gantry. Therefore, uniformity of magnetic field is quite important, since scanned beams traverse through these superconducting magnets before reaching to the isocenter. In the present work, we precisely measured the magnetic-field distributions of the superconducting magnets for the rotating gantry. We used Hall probes to measure the magnetic-flux density. The magnetic-field distributions were determined by measuring Hall voltage, while moving the Hall probes on a rail, which has the same curvature as a center trajectory of beams. The measured-field distributions were compared with designed distributions by using a three-dimensional electromagnetic-field solver, the OPERA-3D code. Furthermore, beam-tracking simulations were performed by using the measured magnetic-field distributions to verify the design of the superconducting magnets. |
|||||
書誌情報 |
IPAC2014: Proceedings of the 5th International Particle Accelerator Conference 巻 IPAC, 号 14, p. 2159-2161, 発行日 2014-08 |
|||||
出版者 | ||||||
出版者 | JACoW | |||||
ISBN | ||||||
識別子タイプ | ISBN | |||||
関連識別子 | 978-3-95450-132-8 |