ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

High spatial resolution microdosimetry with ΔE-E detector on C-12 beam: Monte Carlo simulations

https://repo.qst.go.jp/records/54554
https://repo.qst.go.jp/records/54554
395ae9d0-cb6c-491d-a516-8af1ff6861d8
Item type 会議発表論文 / Conference Paper(1)
公開日 2015-06-29
タイトル
タイトル High spatial resolution microdosimetry with ΔE-E detector on C-12 beam: Monte Carlo simulations
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Linh, Tran Thuy

× Linh, Tran Thuy

WEKO 557234

Linh, Tran Thuy

Search repository
Prokopovich, Anthony

× Prokopovich, Anthony

WEKO 557235

Prokopovich, Anthony

Search repository
Petasecca, Marco

× Petasecca, Marco

WEKO 557236

Petasecca, Marco

Search repository
Fazzi, Alberto

× Fazzi, Alberto

WEKO 557237

Fazzi, Alberto

Search repository
Sagia, Eleni

× Sagia, Eleni

WEKO 557238

Sagia, Eleni

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 557239

Matsufuji, Naruhiro

Search repository
Anatoly, Rozenfeld

× Anatoly, Rozenfeld

WEKO 557240

Anatoly, Rozenfeld

Search repository
al., et

× al., et

WEKO 557241

al., et

Search repository
Tran Thuy Linh

× Tran Thuy Linh

WEKO 557242

en Tran Thuy Linh

Search repository
Prokopovich Anthony

× Prokopovich Anthony

WEKO 557243

en Prokopovich Anthony

Search repository
Petasecca Marco

× Petasecca Marco

WEKO 557244

en Petasecca Marco

Search repository
Fazzi Alberto

× Fazzi Alberto

WEKO 557245

en Fazzi Alberto

Search repository
Sagia Eleni

× Sagia Eleni

WEKO 557246

en Sagia Eleni

Search repository
松藤 成弘

× 松藤 成弘

WEKO 557247

en 松藤 成弘

Search repository
Anatoly Rozenfeld

× Anatoly Rozenfeld

WEKO 557248

en Anatoly Rozenfeld

Search repository
抄録
内容記述タイプ Abstract
内容記述 The response of ΔE-E telescope in C12 ion beam at defined positions within the Bragg peak at different depths with 0.5mm step was studied using Geant4 Monte Carlo toolkit. The microdosimetric spectra derived from ΔE stage response using assumption that average chord is 1.8 μm along with simulated scatter plots for the same points. It was demonstrated that microdosimetric spectra is changing dramatically within 0.5 mm depth increments close to and at distal part of the BP that is impossible to observe with TEPC. Fragments (He4, He3, Li7, Be9, B11) and neutrons contributed to microdosimetric spectra and to YD have been analyzed for each position.
書誌情報 Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)

発行日 2015-02
出版者
出版者 IEEE
ISBN
識別子タイプ ISBN
関連識別子 978-1-4799-0533-1
DOI
識別子タイプ DOI
関連識別子 http://dx.doi.org/10.1109/NSSMIC.2013.6829010
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 22:59:32.166906
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3