ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Carbon Ion Radiotherapy in Patients with Prostate Cancer

https://repo.qst.go.jp/records/54430
https://repo.qst.go.jp/records/54430
d01c8a6e-54e0-426c-a05a-64d060dc17c8
Item type 会議発表論文 / Conference Paper(1)
公開日 2013-12-12
タイトル
タイトル Carbon Ion Radiotherapy in Patients with Prostate Cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 555931

Tsuji, Hiroshi

Search repository
Nomiya, Takuma

× Nomiya, Takuma

WEKO 555932

Nomiya, Takuma

Search repository
Maruyama, Katsuya

× Maruyama, Katsuya

WEKO 555933

Maruyama, Katsuya

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 555934

Kamada, Tadashi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 555935

Tsujii, Hirohiko

Search repository
辻 比呂志

× 辻 比呂志

WEKO 555936

en 辻 比呂志

Search repository
野宮 琢磨

× 野宮 琢磨

WEKO 555937

en 野宮 琢磨

Search repository
丸山 克也

× 丸山 克也

WEKO 555938

en 丸山 克也

Search repository
鎌田 正

× 鎌田 正

WEKO 555939

en 鎌田 正

Search repository
辻井 博彦

× 辻井 博彦

WEKO 555940

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract:
A clinical trial of carbon ion radiotherapy (C-ion RT) for prostate cancer was started in 1995 at the National Institute of Radiological Sciences (NIRS), taking advantage of the quality of carbon ion beams to distinguish dose concentrations and establish a high anticancer efficacy. First, two phase I/II dose escalation studies with a fractionation of 20 fractions over five weeks were conducted to establish techniques using carbon ion beams to determine the optimal dose of fractionation. Then, a phase II study of 20 fractions was performed to validate the feasibility and efficacy of C-ion RT delivered in 20 fractions, which was successfully completed in 2003. Thereafter, a study of hypofractionated C-ion RT in16 fractions over four weeks was performed. Consequently, the incidence of late radiation toxicity decreased without an increase in tumor recurrence. Currently, hypofractionated radiotherapy in 12 fractions over three weeks with scanning irradiation is being evaluated in clinical practice.
Up to February 2013, 1,733 patients underwent C-ion RT, including 552 patients treated with 20 fractions, 1,107 patients treated with 16 fractions, and 64 patients treated with 12 fractions. Of these patients, 53% were categorized as high-risk. The five-year overall survival rate and biochemical relapse-free rate in the entire group were 95.1% and 90.7%, respectively. All risk factors had a significant influence on both biochemical control and patient survival. Biochemical control was not affected by the alteration of dose fractionation; however, the incidence of late radiation toxicity decreased in association with a decrease in the fraction number.
書誌情報 NIRS&MedAustron Joint Symposium on Carbon Ion Radiotherapy

p. 32-37, 発行日 2013-12
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:01:02.568762
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3