WEKO3
アイテム
{"_buckets": {"deposit": "cbf48b0d-f049-4f0f-9714-6b227ae46d78"}, "_deposit": {"created_by": 1, "id": "54282", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54282"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054282", "sets": ["2"]}, "author_link": ["554443", "554445", "554441", "554447", "554444", "554439", "554448", "554440", "554449", "554450", "554446", "554442"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "NIRS-M-232", "bibliographicPageStart": "66", "bibliographicVolumeNumber": "第5回", "bibliographic_titles": [{"bibliographic_title": "技術と安全の報告会報告集"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PIXE分析は国内外の研究機関において、様々な研究分野で利用されており、近年、環境科学および医学生物学分野の応用研究が増加し、定量分析へのニーズが高まっている。PIXE分析で汎用されている測定試料の形状・形態として、圧縮成型した粉末状サンプル、液体試料の滴下乾燥サンプル、あるいは凍結組織切片等の薄切サンプルなどがあり、定量分析に向けて各々の形状・形態に合わせた分析標準試料の確立が望まれている。そこで我々は、錠剤型、滴下乾燥および薄切の3種類の分析標準を試作し、その作成方法の検討や均質性等の性状評価を進めている。\n本報告会では、試作した3種類の分析標準試料を実際にPIXE分析に供し、得られた性状評価結果を報告する。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "磯, 浩之"}], "nameIdentifiers": [{"nameIdentifier": "554439", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武田, 志乃"}], "nameIdentifiers": [{"nameIdentifier": "554440", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "及川, 将一"}], "nameIdentifiers": [{"nameIdentifier": "554441", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西, 輝昭"}], "nameIdentifiers": [{"nameIdentifier": "554442", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川, 剛弘"}], "nameIdentifiers": [{"nameIdentifier": "554443", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "樋口, 有一"}], "nameIdentifiers": [{"nameIdentifier": "554444", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関, 等"}], "nameIdentifiers": [{"nameIdentifier": "554445", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武田 志乃", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "及川 将一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小西 輝昭", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石川 剛弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "今関 等", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "554450", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "環境および生物試料に適応したPIXE分析標準試料の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "環境および生物試料に適応したPIXE分析標準試料の開発"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54282", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-02-03"}, "publish_date": "2011-02-03", "publish_status": "0", "recid": "54282", "relation": {}, "relation_version_is_last": true, "title": ["環境および生物試料に適応したPIXE分析標準試料の開発"], "weko_shared_id": -1}
環境および生物試料に適応したPIXE分析標準試料の開発
https://repo.qst.go.jp/records/54282
https://repo.qst.go.jp/records/542826caef155-9119-4279-8ea4-14717b1c9131
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-02-03 | |||||
タイトル | ||||||
タイトル | 環境および生物試料に適応したPIXE分析標準試料の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
磯, 浩之
× 磯, 浩之× 武田, 志乃× 及川, 将一× 小西, 輝昭× 石川, 剛弘× 樋口, 有一× 今関, 等× 武田 志乃× 及川 将一× 小西 輝昭× 石川 剛弘× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PIXE分析は国内外の研究機関において、様々な研究分野で利用されており、近年、環境科学および医学生物学分野の応用研究が増加し、定量分析へのニーズが高まっている。PIXE分析で汎用されている測定試料の形状・形態として、圧縮成型した粉末状サンプル、液体試料の滴下乾燥サンプル、あるいは凍結組織切片等の薄切サンプルなどがあり、定量分析に向けて各々の形状・形態に合わせた分析標準試料の確立が望まれている。そこで我々は、錠剤型、滴下乾燥および薄切の3種類の分析標準を試作し、その作成方法の検討や均質性等の性状評価を進めている。 本報告会では、試作した3種類の分析標準試料を実際にPIXE分析に供し、得られた性状評価結果を報告する。 |
|||||
書誌情報 |
技術と安全の報告会報告集 巻 第5回, 号 NIRS-M-232, p. 66, 発行日 2010-07 |