ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Analysis of body size effects on the WBC

https://repo.qst.go.jp/records/54216
https://repo.qst.go.jp/records/54216
b5836092-a31a-43cd-8a82-1e833151084a
Item type 会議発表論文 / Conference Paper(1)
公開日 2010-05-26
タイトル
タイトル Analysis of body size effects on the WBC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Enomoto, Hiroko

× Enomoto, Hiroko

WEKO 553551

Enomoto, Hiroko

Search repository
Nakano, Takashi

× Nakano, Takashi

WEKO 553552

Nakano, Takashi

Search repository
Matsumoto, Masaki

× Matsumoto, Masaki

WEKO 553553

Matsumoto, Masaki

Search repository
Suzuki, Tosikazu

× Suzuki, Tosikazu

WEKO 553554

Suzuki, Tosikazu

Search repository
榎本 宏子

× 榎本 宏子

WEKO 553555

en 榎本 宏子

Search repository
仲野 高志

× 仲野 高志

WEKO 553556

en 仲野 高志

Search repository
松本 雅紀

× 松本 雅紀

WEKO 553557

en 松本 雅紀

Search repository
鈴木 敏和

× 鈴木 敏和

WEKO 553558

en 鈴木 敏和

Search repository
抄録
内容記述タイプ Abstract
内容記述 In an accidental intake of radionuclides, identification of the nuclides and determination of the exact amount in the body are important. The identification can be done by measurements using high resolution Ge semiconductor detectors in a whole body counter (WBC). Body size affects the determination of amount. Various BOMAB phantoms were measured to confirm the effects. The measurements were carried with the WBC owned by the National Institute of Radiological Sciences (NIRS). This WBC is composed of six Ge semiconductor detectors. First, adult male BOMAB phantoms which uniformly enclosed Ba-133, Cs-137, Co-60 and K-40 sources were measured. Then the detection efficiencies of various energies were gotten and size influence was calculated by extrapolation from the results of similarity measurements of five BOMAB phantoms which uniformly enclosed a K-40 source; the five phantoms were of a 4 year-old, a 10 year-old, an adult female, an adult male and a 95th percentile male. Moreover, it is necessary to clarify the dependence of the efficiency on the distribution of the nuclides just after they are taken into the body. Point sources were affixed between the chest and the waist as a local distribution. Although the ratio was generally 1 near 80 keV, it was 1.3 to 1.6 times that from 350 keV to 1333 keV. Furthermore, the point sources were affixed on the surface of the BOMAB phantoms. This situation was assumed as the case where surface contamination cannot be removed such as when there is a wound. For the same radioactivity, it turned out that the internal contamination had rather higher detection efficiency than surface contamination on the adult BOMAB. On the contrary, the detection efficiency of surface contamination became higher than that for internal contamination for smaller body size.
書誌情報 Proceedings of the Asian and Oceanic Congress for Radiation Protection

p. 000, 発行日 2010-05
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:03:33.789095
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3