ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

A Simulation Study of Lognormal Measurement Error Effect -Discrimination Problem of Radon and Thoron-

https://repo.qst.go.jp/records/54035
https://repo.qst.go.jp/records/54035
6535ee8f-edd7-4cde-bde8-1e2f4e6b1b12
Item type 会議発表論文 / Conference Paper(1)
公開日 2008-09-13
タイトル
タイトル A Simulation Study of Lognormal Measurement Error Effect -Discrimination Problem of Radon and Thoron-
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Doi, Kazutaka

× Doi, Kazutaka

WEKO 551606

Doi, Kazutaka

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 551607

Tokonami, Shinji

Search repository
Kobayashi, Yosuke

× Kobayashi, Yosuke

WEKO 551608

Kobayashi, Yosuke

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 551609

Yonehara, Hidenori

Search repository
Yoshinaga, Shinji

× Yoshinaga, Shinji

WEKO 551610

Yoshinaga, Shinji

Search repository
土居 主尚

× 土居 主尚

WEKO 551611

en 土居 主尚

Search repository
床次 眞司

× 床次 眞司

WEKO 551612

en 床次 眞司

Search repository
小林 羊佐

× 小林 羊佐

WEKO 551613

en 小林 羊佐

Search repository
米原 英典

× 米原 英典

WEKO 551614

en 米原 英典

Search repository
吉永 信治

× 吉永 信治

WEKO 551615

en 吉永 信治

Search repository
抄録
内容記述タイプ Abstract
内容記述 Several case-control studies have indicated an increased risk of lung cancer linked to indoor radon exposure. For a precise evaluation of radon-related lung cancer risk, however, contribution of thoron should be considered. There are a lot of studies in which passive type radon detectors are used without thoron discrimination techniques. Therefore, these passive type radon detectors may be strongly affected to the presence of thoron in case they are installed near a wall or floor as potential thoron sources. The thoron effect we consider here is an increase of radon signal in the radon detectors without the discrimination technique. This problem is classified as a part of measurement error problem in statistical literatures and the thoron is considered as a possible source of measurement error. In general, concentrations of radon and thoron follow a lognormal distribution. The effects of measurement error following normal distribution have been studied well, but there are few studies on measurement error following non-normal distribution. In order to evaluate the effect of measurement error due to thoron, we conducted a simulation study. We assumed a case-control study of lung cancer and indoor radon with hypothetical data where radon concentrations were measured with and without discrimination of thoron concentrations. We also assumed that logistic regression was used, and that the concentrations of radon and thoron were correlated, following lognormal distribution. The thoron disturbance in radon measurement resulted in an approximately 90% downward bias in the effect of radon, and this bias was almost constant when the parameters were varied. The downward bias was consistent with results from previous studies taking measurement error following normal distribution into account. It was confirmed that the effect of lognormal measurement error is concordant with the normal measurement error in this case.
書誌情報 Proceedings of International Congress of the International Radiation Protection Association

p. 000, 発行日 2008-10
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:05:37.989914
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3