ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Remote Sensing of Nuclear Radiation Leakage by a Direction Finding Dtector

https://repo.qst.go.jp/records/53822
https://repo.qst.go.jp/records/53822
d354144b-dc1a-40a8-8602-c794b37579e4
Item type 会議発表論文 / Conference Paper(1)
公開日 2007-04-04
タイトル
タイトル Remote Sensing of Nuclear Radiation Leakage by a Direction Finding Dtector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Shirakawa, Yoshiyuki

× Shirakawa, Yoshiyuki

WEKO 549286

Shirakawa, Yoshiyuki

Search repository
et.al

× et.al

WEKO 549287

et.al

Search repository
白川 芳幸

× 白川 芳幸

WEKO 549288

en 白川 芳幸

Search repository
抄録
内容記述タイプ Abstract
内容記述 There is a considerable interest in measuring an incident direction of gamma rays for searching radioactive materials and contaminations from the viewpoint of radiation protection and safety, or in finding out a nuclear accident for a quick response. . In order to meet this demand, a new gamma ray detector, which positively raises directional sensitivity against incoming gamma rays, has been developed. This detector is composed of three kinds of different scintillators and a photomultiplier tube. The types of scintillators are NaI(Tl), CsI(Tl), and BGO. The section shape of each scintillator is the sector of 120 degrees. The one cylindrical scintillator is made by optically connecting three sectorial scintillators. Gamma rays penetrate along a straight path through each scintillator of the detector, and the length of each path is dependent on the incident direction. Therefore the probability of photoelectric effect in each scintillator is changed, according to incident directions of gamma rays. As a result, the numbers of gamma ray counts of three peaks observed in a spectrum obtained by a multi-channel analyzer (MCA) have a strong dependency with the direction. The response curve of each scintillator with respect to a peak count and an incident direction was obtained by experiments using a gamma ray source of Cs-137. It has been recognized that these response curves have sensitivity in the total range from 0 to 360 degrees. Therefore the proposed detector has the possibility that the direction can be identified and will be used as a radiation monitoring post or a radiation survey meter.
書誌情報 International Symposium on Industrial Electronics, 9-13 July 2006, ETS-Downtown Montreal, Canada

p. 2728-2731, 発行日 2006-07
出版者
出版者 IEEE
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:08:09.810736
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3