ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Field inhomogeneity may substantially affect hyperpolarised 129Xe rat head spectra

https://repo.qst.go.jp/records/53768
https://repo.qst.go.jp/records/53768
44c72e98-d12b-4c6c-a565-d2e79c079b88
Item type 会議発表論文 / Conference Paper(1)
公開日 2006-11-28
タイトル
タイトル Field inhomogeneity may substantially affect hyperpolarised 129Xe rat head spectra
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kershaw, Jeffrey

× Kershaw, Jeffrey

WEKO 548746

Kershaw, Jeffrey

Search repository
Nakamura, Kazuhiro

× Nakamura, Kazuhiro

WEKO 548747

Nakamura, Kazuhiro

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 548748

Kanno, Iwao

Search repository
et.al

× et.al

WEKO 548749

et.al

Search repository
Kershaw Jeffrey

× Kershaw Jeffrey

WEKO 548750

en Kershaw Jeffrey

Search repository
中村 和浩

× 中村 和浩

WEKO 548751

en 中村 和浩

Search repository
菅野 巖

× 菅野 巖

WEKO 548752

en 菅野 巖

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recent results have shown that hyperpolarized 129Xe rat head spectra may be affected by changes in the shimming procedure [1]. An example is shown in Fig 1, where the shimming was concentrated on 8 mm thick slices in the cerebellum and brain. The shape of the second peak is clearly affected by the change shimming; however this pattern is not consistent from animal to animal, suggesting that the differences do not simply arise from the choice of different slices to shim on.
In preparation for the acquisition of 129Xe rat head spectra, our group has up to this point shimmed the field by monitoring the width and symmetry of the proton resonance whilst altering the shim-coil currents. Unfortunately this method of shimming can be tedious and is liable to produce nonideal shim states because of the number of parameters involved in the optimization process. Moreover, the field homogeneity may be distorted by the boundaries between tissue and void spaces. To investigate the homogeneity of the field in rat head and as a first step towards studying the possible effects inhomogeneity may have on the 129Xe dissolved phase spectrum, we have implemented a field-mapping algorithm. The results indicate that even with a supposedly well-shimmed state, there is a substantial variation in the field that may cause or contribute to anomalies in rat head spectra.
書誌情報 Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition

巻 14, p. 2544, 発行日 2006
ISSN
収録物識別子タイプ ISSN
収録物識別子 1524-6965
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:08:50.122917
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3