  1. プロシーディングス

Estimation of scattered radiation amount and its effects on image quality in 4D CT

https://repo.qst.go.jp/records/53594
https://repo.qst.go.jp/records/53594
b338081d-d85a-491e-982a-c413495ef51c
Item type 会議発表論文 / Conference Paper(1)
公開日 2005-10-15
タイトル
タイトル Estimation of scattered radiation amount and its effects on image quality in 4D CT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichirou

× Mori, Shinichirou

WEKO 546994

Mori, Shinichirou

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 546995

Endo, Masahiro

Search repository
et.al

× et.al

WEKO 546996

et.al

Search repository
森 慎一郎

× 森 慎一郎

WEKO 546997

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 546998

en 遠藤 真広

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have developed a prototype of 4-dimensional (4D) CT-scanner that employs continuous rotation of cone-beam, the number of elements are 912 channels x 256 segments; element size is approximately 1mm x 1mm. Scanning time is 1.0sec/rotation. Data sampling rate is 900 views (frames)/sec. The potential drawback of cone beam CT is a larger amount of scattered x-rays than conventional CT-scanner. Our purpose in this work was to estimate scattered-to-primary ratio (S/P) and observe its effects on the reconstructed images as variation of a beam width (5-128mm).
S/P was measured by scanning cylindrical water phantom and interrupting the primary with Pb disk. The effects of scattered radiation on the images was evaluated with noise and uniformity of CT number, the low contrast detectability and the differences of CT number between air cavity in the water phantom and air region outside it.
\nThough S/P increased as the beam width became wider, noise and uniformity of CT numbers depended little on the beam width. Low contrast detectability did not depend on it. However CT numbers differed 38 at 5mm beam width and 67 at 128mm beam width between the air cavity and the air region outside. S/P of 200mm-diam-water phantom for 120kVp was approximately 8% (128mm beam width) and approximately 1% (10mm beam width).
The results suggested that scattered radiation seemed little effect on image quality except quantitativeness of CT-number in 4D CT.
書誌情報 Radiology

p. 000, 発行日 2003
ISSN
収録物識別子タイプ ISSN
収録物識別子 0033-8419
戻る
0
views
See details
Views