ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

The CALET Instrument for Experiment on the ISS

https://repo.qst.go.jp/records/53581
https://repo.qst.go.jp/records/53581
883b69a8-85fa-43aa-a53d-28687679b17d
Item type 会議発表論文 / Conference Paper(1)
公開日 2005-10-06
タイトル
タイトル The CALET Instrument for Experiment on the ISS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Torii, Syoji

× Torii, Syoji

WEKO 546906

Torii, Syoji

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 546907

Kitamura, Hisashi

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 546908

Uchihori, Yukio

Search repository
et.al

× et.al

WEKO 546909

et.al

Search repository
鳥居 祥二

× 鳥居 祥二

WEKO 546910

en 鳥居 祥二

Search repository
北村 尚

× 北村 尚

WEKO 546911

en 北村 尚

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 546912

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 We propose the CALorimetric Electron Telescope (CALET) mission for Japanese Experiment Module, Exposed Facilisty (JEM-EF) on ISS to address some of the most profound questions in particle astrophysics. CALET is composed of two kinds of calorimeter, an imaging calorimeter, IMC, at upper part and a total absorption calorimeter, TASC, at lower part. The IMC is employed to detect the shower profile by using scintillating fibers with 64-anode PMT read-out system. The TASC is consisted of BGO logs to measure the energy deposits in each shower. Total weight of the payload is nearly 2,500 kg and the geometrical factor for electrons is about 1 m2 sr. CALET has a unique capability to measure electrons and gamma-rays beyond 1 TeV since it can have a superior hadron rejection power of 10^6 for electrons and much better for gammarays. It can also measure protons and heavy nuclei in proximity of the Knee. The energy resolution for electromagnetic particles is better than a few % above 100 GeV. We will present a baseline design of the detector, and report the present status of detector development. Compatibility of the detector with the JEM Exposed Facility will also be discussed.
書誌情報 Proceedings of International Cosmic Ray Conference

巻 OG, p. 000, 発行日 2005-08
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:10:59.768625
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3