Performance of the CALET Calorimeter by Accelerator Beam Test

https://repo.qst.go.jp/records/53579
https://repo.qst.go.jp/records/53579
9fb40674-66dd-4afd-bbc4-7a2c467d03b6
Item type 会議発表論文 / Conference Paper(1)
公開日 2005-10-06
タイトル
タイトル Performance of the CALET Calorimeter by Accelerator Beam Test
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Katayose, Yusaku

× Katayose, Yusaku

WEKO 546890

Katayose, Yusaku

Search repository
Torii, Syoji

× Torii, Syoji

WEKO 546891

Torii, Syoji

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 546892

Kitamura, Hisashi

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 546893

Uchihori, Yukio

Search repository
et.al

× et.al

WEKO 546894

et.al

Search repository
片寄 祐作

× 片寄 祐作

WEKO 546895

en 片寄 祐作

Search repository
鳥居 祥二

× 鳥居 祥二

WEKO 546896

en 鳥居 祥二

Search repository
北村 尚

× 北村 尚

WEKO 546897

en 北村 尚

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 546898

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing the CALET (CALorimetric Electron Telescope) instrument for bserving high energy electrons and gamma rays on ISS. For confirming the CALET capability expected by simulations, we made a scale model of CALET with a size of 2/3 in thickness and had the experimental tests by using beams available in CERN. The beams used are 50GeV, 100GeV electron and 150 GeV proton. The energy resolution is sigma/E = 4.0+-0.1 percent and 2.25+-0.04 percent for 50GeV and 100GeV electrons, respectively. About 97.3 percent of protons can be rejected by shower image with Total Absorption Calorimeter, TASC, while approximately 96.8 percent of electrons were correctly identified. The performance of the scale model was also investigated by Monte Carlo simulation to compare with the results by beam tests. We confirmed good consistency between simulation and the beam test.
書誌情報 Proceedings of International Cosmic Ray Conference

巻 OG, p. 000, 発行日 2005-08
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:11:01.116082
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3