Analytical image reconstruction of cone-beam projections from limited angle Compton camera data

https://repo.qst.go.jp/records/53321
https://repo.qst.go.jp/records/53321
cbb03054-b9ce-43ff-9921-92ffe4415f9b
Item type 会議発表論文 / Conference Paper(1)
公開日 2004-05-05
タイトル
タイトル Analytical image reconstruction of cone-beam projections from limited angle Compton camera data
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tomitani, Takehiro

× Tomitani, Takehiro

WEKO 544152

Tomitani, Takehiro

Search repository
Hirasawa, Masahiko

× Hirasawa, Masahiko

WEKO 544153

Hirasawa, Masahiko

Search repository
富谷 武浩

× 富谷 武浩

WEKO 544154

en 富谷 武浩

Search repository
平澤 雅彦

× 平澤 雅彦

WEKO 544155

en 平澤 雅彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since the integration of gamma-rays on a cone is
measured with Compton cameras, some sort of image reconstruction
method is necessary. Parra developed an analytical reconstruction
algorithm based on a spherical-harmonics expansion
of projection data that covers the entire scattering-angle range.
The scattering-angle range is limited due to the electrical noise of
the detector and due to the finite detector configuration. In this
article, a reconstruction algorithm from the projection of a limited
scattering-angle range is presented. The algorithm is based on an
inversion of the summed back-projection. The variance of the
reconstructed image of a uniform source was analyzed and is proportional
to the third power of the number of expansion terms.
Thus, window functions are introduced to suppress noise at the
cost of spatial resolution. The dependency of the spatial resolution
on the number of expansion terms was analyzed. The dependency
of the variance on the spatial resolution was found to be that variance
is proportional to (spatial resolution)^(-1/3).
書誌情報 IEEE Nuclear Science Symposium Conference Record : Nuclear Science Symposium, Medical Imaging Conference

巻 2002, p. M11-105, 発行日 2003-05
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:13:58.159465
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3