ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

https://repo.qst.go.jp/records/53137
https://repo.qst.go.jp/records/53137
658c7820-7d23-4336-aea9-75a024d1d7bf
Item type 会議発表論文 / Conference Paper(1)
公開日 2003-10-20
タイトル
タイトル Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Uemura, Koji

× Uemura, Koji

WEKO 542166

Uemura, Koji

Search repository
Toyama, Hinako

× Toyama, Hinako

WEKO 542167

Toyama, Hinako

Search repository
Miyamoto, Tadaaki

× Miyamoto, Tadaaki

WEKO 542168

Miyamoto, Tadaaki

Search repository
Mori, Yutaka

× Mori, Yutaka

WEKO 542169

Mori, Yutaka

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 542170

Yoshikawa, Kyosan

Search repository
上村 幸司

× 上村 幸司

WEKO 542171

en 上村 幸司

Search repository
外山 比南子

× 外山 比南子

WEKO 542172

en 外山 比南子

Search repository
宮本 忠昭

× 宮本 忠昭

WEKO 542173

en 宮本 忠昭

Search repository
森 豊

× 森 豊

WEKO 542174

en 森 豊

Search repository
吉川 京燦

× 吉川 京燦

WEKO 542175

en 吉川 京燦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images.
Materials and Methods: Perfusion, ventilation and blood pool images with Tc99m labeled radiopharmaceuticals and SPECT, tumor images with 11C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively.
Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was found to be possible to evaluate the therapeutic gain of heavy particle therapy sequentially by using the same ROI.
Conclusion: This method is useful for evaluating the therapeutic gain of heavy particle therapy performed on patients with lung cancer quantitatively and sequentially. Registration of chest SPECT, PET and/or X-ray CT images by using AMIR method got good result for all of the registrations.
書誌情報 World Journal of Nuclear Medicine

巻 1, 号 Suppl.2, p. S229-S229, 発行日 2002-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 1450-1147
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:16:03.630000
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3