ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

ICP-MS analysis of environmental plutonium.

https://repo.qst.go.jp/records/52990
https://repo.qst.go.jp/records/52990
0074c5a3-6014-4ab4-bc9c-76f17da7c5a3
Item type 会議発表論文 / Conference Paper(1)
公開日 2003-01-23
タイトル
タイトル ICP-MS analysis of environmental plutonium.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Muramatsu, Yasuyuki

× Muramatsu, Yasuyuki

WEKO 540532

Muramatsu, Yasuyuki

Search repository
Yoshida, Satoshi

× Yoshida, Satoshi

WEKO 540533

Yoshida, Satoshi

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 540534

Tagami, Keiko

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 540535

Uchida, Shigeo

Search repository
Ruehm, Werner

× Ruehm, Werner

WEKO 540536

Ruehm, Werner

Search repository
村松 康行

× 村松 康行

WEKO 540537

en 村松 康行

Search repository
吉田 聡

× 吉田 聡

WEKO 540538

en 吉田 聡

Search repository
田上 恵子

× 田上 恵子

WEKO 540539

en 田上 恵子

Search repository
内田 滋夫

× 内田 滋夫

WEKO 540540

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 ICP-MS was applied to determine the concentration of 239Pu and 240Pu and their isotope ratio in environmental samples. Two types of chromatographic resins, Dowex 1X8 and TEVA, were examined for their applicability to the separation of Pu from the matrix elements. Sufficient decontamination factors (104 - 105) for many matrix elements including U, which interferes with the detection of mass 239, were obtained with both resins. The detection limit of Pu by quadrupole-type ICP-MS was about 0.02 pg ml-1 in the sample solution. High resolution-type ICP-MS was also tested for its sensitivity and the detection limit was found to be about one order of magnitude better than this value. Analytical results of 239+240Pu in standard reference materials (IAEA-134, -135, -367, -368 and -SOIL-6) indicated that the accuracy of the method was satisfactory. Data on the 240Pu/239Pu atom ratios in these reference materials, which are scarce in the literature, were also obtained. Compared with alpha-spectrometry, the ICP-MS method has significant advantages in terms of prompt measurement time, simple analytical procedures and capability of determining the 240Pu/239Pu ratio. The 240Pu/239Pu atom ratios observed in seven soil samples collected from different places in Japan ranged from 0.168 to 0.181, which are comparable to the global fallout ratio. Analytical results for samples originating from different places worldwide (including contaminated areas) showed a wide range of the 240Pu/239Pu atom ratio (0.04 - 0.4) according to the source of the Pu. Determination of the 240Pu/239Pu ratio is useful to identify the origin of the contamination.
書誌情報 Plutonium in the Environment (Radioactivity in the Environment ; v. 1)

p. 63-77, 発行日 2001
出版者
出版者 Elsevier
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:17:44.730905
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3