The new technological solution for the JT-60SA quench protection circuits

https://repo.qst.go.jp/records/49617
https://repo.qst.go.jp/records/49617
fc20bb79-3768-4e44-aa82-099c881a6619
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-02-13
タイトル
タイトル The new technological solution for the JT-60SA quench protection circuits
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Gaio, Elena

× Gaio, Elena

WEKO 501261

Gaio, Elena

Search repository
Maistrello, Alberto

× Maistrello, Alberto

WEKO 501262

Maistrello, Alberto

Search repository
Novello, Luca

× Novello, Luca

WEKO 501263

Novello, Luca

Search repository
Matsukawa, Makoto

× Matsukawa, Makoto

WEKO 501264

Matsukawa, Makoto

Search repository
Perna, Mauro

× Perna, Mauro

WEKO 501265

Perna, Mauro

Search repository
Ferro, Alberto

× Ferro, Alberto

WEKO 501266

Ferro, Alberto

Search repository
Yamauchi, Kunihito

× Yamauchi, Kunihito

WEKO 501267

Yamauchi, Kunihito

Search repository
Piovan, Roberto

× Piovan, Roberto

WEKO 501268

Piovan, Roberto

Search repository
松川 誠

× 松川 誠

WEKO 501269

en 松川 誠

Search repository
山内 邦仁

× 山内 邦仁

WEKO 501270

en 山内 邦仁

Search repository
抄録
内容記述タイプ Abstract
内容記述 An advanced technology has been developed and employed for the main circuit breakers (CB) of the quench protection circuits (QPC) of the superconducting coils of JT-60SA: it consists in a Hybrid mechanical-static CB (HCB) composed of a mechanical Bypass switch (BPS) for conducting the continuous current, in parallel to a static circuit breaker (SCB) based on integrated gate commutated thyristor (IGCT) for current interruption. It was the result of a R&D program carried out since 2006 to identify innovative solutions for the interruption of high dc current, able to improve the maintainability and availability of the CB. The HCB developed for the JT-60SA QPC is the first realization of a dc circuit breaker based on this design approach for interrupting current of some tens of kA with reapplied voltage of some kV. It also represents the first application of hybrid technology with IGCT for protection of superconducting magnets in fusion experiments. The paper aims at giving a comprehensive overview of the main R&D activities devoted to the development of this new technological approach; then, the key aspects of the design, manufacturing and testing of the QPCs for JT-60SA, successfully completed in Naka Site in summer 2015 are presented. Finally, the significance of this research is discussed and the possible future developments, in particular in view of DEMO fusion reactor, are outlined.
書誌情報 Nuclear Fusion

巻 58, 号 7, p. 075001, 発行日 2018-06
出版者
出版者 IOP Publishing
DOI
識別子タイプ DOI
関連識別子 10.1088/1741-4326/aac1c4
関連サイト
識別子タイプ URI
関連識別子 iopscience.iop.org/article/10.1088/1741-4326/aac1c4
関連名称 iopscience.iop.org/article/10.1088/1741-4326/aac1c4
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:18:58.277524
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3