ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Evaluation of the temperature dependence of the Cesium deposition on the plasma grid in the JT-60SA negative ion source

https://repo.qst.go.jp/records/49564
https://repo.qst.go.jp/records/49564
e6c99ae4-7d92-4369-a566-7c6bc5421b57
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-02-06
タイトル
タイトル Evaluation of the temperature dependence of the Cesium deposition on the plasma grid in the JT-60SA negative ion source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, M.

× Yoshida, M.

WEKO 876445

Yoshida, M.

Search repository
Oohara, W.

× Oohara, W.

WEKO 876446

Oohara, W.

Search repository
市川, 雅浩

× 市川, 雅浩

WEKO 876447

市川, 雅浩

Search repository
平塚, 淳一

× 平塚, 淳一

WEKO 876448

平塚, 淳一

Search repository
梅田, 尚孝

× 梅田, 尚孝

WEKO 876449

梅田, 尚孝

Search repository
小島, 有志

× 小島, 有志

WEKO 876450

小島, 有志

Search repository
柏木, 美恵子

× 柏木, 美恵子

WEKO 876451

柏木, 美恵子

Search repository
Ichikawa, Masahiro

× Ichikawa, Masahiro

WEKO 876452

en Ichikawa, Masahiro

Search repository
Hiratsuka, Junichi

× Hiratsuka, Junichi

WEKO 876453

en Hiratsuka, Junichi

Search repository
Umeda, Naotaka

× Umeda, Naotaka

WEKO 876454

en Umeda, Naotaka

Search repository
Kojima, Atsushi

× Kojima, Atsushi

WEKO 876455

en Kojima, Atsushi

Search repository
Kashiwagi, Mieko

× Kashiwagi, Mieko

WEKO 876456

en Kashiwagi, Mieko

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to evaluate deposition of cesium (Cs) in the plasma grid (PG) and investigate the origin of the gradual degradation of the negative ion current in a 100 s long pulsed operation in the JT-60SA negative ion source, Cs behavior
in the source is model. To do this, Cs adsorption/desorption coefficient with a wide range of temperature is experimentally measured by a surface ionization detector and a quartz crystal microbalance. As a result, both of the adsorption and desorption are drastically varied at temperature range from room temperature to 100 oC. Based on these data, the model calculates the amounts of the Cs mass in the chamber wall and PG. The calculation result shows that, in the operation, an increase of temperature in the chamber wall (Twall) causes the evaporation of the huge amount of Cs in it. This leads to over pilling-up of Cs in the PG and the slight degradation of the negative ion production. Therefore, it is found that the constant temperature operation is needed to sustain the thickness of the Cs monolayer in the PG, and the Twall is desired to be less than 60 oC to suppress the evaporation of Cs in the chamber wall. According to this model, it is showed that there are many combinations of the temperatures to achieve it with low Cs consumption.
書誌情報 AIP Conference Proseedings

巻 2052, p. 040008, 発行日 2018-12
出版者
出版者 AIP Publishing
DOI
識別子タイプ DOI
関連識別子 10.1063/1.5083742
関連サイト
識別子タイプ URI
関連識別子 https://aip.scitation.org/doi/10.1063/1.5083742
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:05:14.949130
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3