WEKO3
アイテム
Feasibility of carbon-ion radiotherapy for re-irradiation of locoregionally recurrent, metastatic, or secondary lung tumors.
https://repo.qst.go.jp/records/49558
https://repo.qst.go.jp/records/49558eee525b6-24ac-446a-9712-55a1dca0b61a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-02-01 | |||||
タイトル | ||||||
タイトル | Feasibility of carbon-ion radiotherapy for re-irradiation of locoregionally recurrent, metastatic, or secondary lung tumors. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hayashi, Kazuhiko
× Hayashi, Kazuhiko× Yamamoto, Naoyoshi× Karube, Masataka× Nakajima, Mio× Tsuji, Hiroshi× Ogawa, Kazuhiko× Kamada, Tadashi× Hayashi, Kazuhiko× Yamamoto, Naoyoshi× Nakajima, Mio× Tsuji, Hiroshi× Kamada, Tadashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Intrathoracic recurrence after carbon-ion radiotherapy for primary or metastatic lung tumors remains a major cause of cancer-related deaths. However, treatment options are limited. Herein, we report on the toxicity and efficacy of re-irradiation with carbon-ion radiotherapy for locoregionally recurrent, metastatic, or secondary lung tumors. Data of 95 patients with prior intrathoracic carbon-ion radiotherapy who were treated with re-irradiation with carbon-ion radiotherapy at our institution between 2006 and 2016 were retrospectively analyzed. Seventy-three patients (76.8%) had primary lung tumors and 22 patients (23.2%) had metastatic lung tumors. The median dose of initial carbon-ion radiotherapy was 52.8 Gy (relative biological effectiveness) and the median dose of re-irradiation was 66.0 Gy (relative biological effectiveness). None of the patients received concurrent chemotherapy. The median follow-up period after re-irradiation was 18 months. In terms of grade ≥3 toxicities, one patient experienced each of the following: grade 5 bronchopleural fistula, grade 4 radiation pneumonitis, grade 3 chest pain, and grade 3 radiation pneumonitis. The 2-year local control and overall survival rates were 54.0% and 61.9%, respectively. In conclusion, re-irradiation with carbon-ion radiotherapy was associated with relatively low toxicity and moderate efficacy. Re-irradiation with carbon-ion radiotherapy might be an effective treatment option for patients with locoregionally recurrent, metastatic, or secondary lung tumors. | |||||
書誌情報 |
Cancer science 巻 109, 号 5, p. 1562-1569, 発行日 2018-05 |
|||||
出版者 | ||||||
出版者 | Wiley Publishing on behalf of the Japanese Cancer Association | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-9032 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 29498145 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1111/cas.13555 |