ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Feasibility of carbon-ion radiotherapy for re-irradiation of locoregionally recurrent, metastatic, or secondary lung tumors.

https://repo.qst.go.jp/records/49558
https://repo.qst.go.jp/records/49558
eee525b6-24ac-446a-9712-55a1dca0b61a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-02-01
タイトル
タイトル Feasibility of carbon-ion radiotherapy for re-irradiation of locoregionally recurrent, metastatic, or secondary lung tumors.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hayashi, Kazuhiko

× Hayashi, Kazuhiko

WEKO 762655

Hayashi, Kazuhiko

Search repository
Yamamoto, Naoyoshi

× Yamamoto, Naoyoshi

WEKO 762656

Yamamoto, Naoyoshi

Search repository
Karube, Masataka

× Karube, Masataka

WEKO 762657

Karube, Masataka

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 762658

Nakajima, Mio

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 762659

Tsuji, Hiroshi

Search repository
Ogawa, Kazuhiko

× Ogawa, Kazuhiko

WEKO 762660

Ogawa, Kazuhiko

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 762661

Kamada, Tadashi

Search repository
Hayashi, Kazuhiko

× Hayashi, Kazuhiko

WEKO 762662

en Hayashi, Kazuhiko

Search repository
Yamamoto, Naoyoshi

× Yamamoto, Naoyoshi

WEKO 762663

en Yamamoto, Naoyoshi

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 762664

en Nakajima, Mio

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 762665

en Tsuji, Hiroshi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 762666

en Kamada, Tadashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Intrathoracic recurrence after carbon-ion radiotherapy for primary or metastatic lung tumors remains a major cause of cancer-related deaths. However, treatment options are limited. Herein, we report on the toxicity and efficacy of re-irradiation with carbon-ion radiotherapy for locoregionally recurrent, metastatic, or secondary lung tumors. Data of 95 patients with prior intrathoracic carbon-ion radiotherapy who were treated with re-irradiation with carbon-ion radiotherapy at our institution between 2006 and 2016 were retrospectively analyzed. Seventy-three patients (76.8%) had primary lung tumors and 22 patients (23.2%) had metastatic lung tumors. The median dose of initial carbon-ion radiotherapy was 52.8 Gy (relative biological effectiveness) and the median dose of re-irradiation was 66.0 Gy (relative biological effectiveness). None of the patients received concurrent chemotherapy. The median follow-up period after re-irradiation was 18 months. In terms of grade ≥3 toxicities, one patient experienced each of the following: grade 5 bronchopleural fistula, grade 4 radiation pneumonitis, grade 3 chest pain, and grade 3 radiation pneumonitis. The 2-year local control and overall survival rates were 54.0% and 61.9%, respectively. In conclusion, re-irradiation with carbon-ion radiotherapy was associated with relatively low toxicity and moderate efficacy. Re-irradiation with carbon-ion radiotherapy might be an effective treatment option for patients with locoregionally recurrent, metastatic, or secondary lung tumors.
書誌情報 Cancer science

巻 109, 号 5, p. 1562-1569, 発行日 2018-05
出版者
出版者 Wiley Publishing on behalf of the Japanese Cancer Association
ISSN
収録物識別子タイプ ISSN
収録物識別子 1347-9032
PubMed番号
識別子タイプ PMID
関連識別子 29498145
DOI
識別子タイプ DOI
関連識別子 10.1111/cas.13555
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:52:29.836678
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3