WEKO3
アイテム
Graphite Furnace Atomic Absorption Spectrometric Evaluation of Iron Excretion in Mouse Urine Caused by Whole-Body Gamma Irradiation
https://repo.qst.go.jp/records/49533
https://repo.qst.go.jp/records/49533d7dcb723-a682-4c7c-8695-afe09c9c214d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-12-13 | |||||
タイトル | ||||||
タイトル | Graphite Furnace Atomic Absorption Spectrometric Evaluation of Iron Excretion in Mouse Urine Caused by Whole-Body Gamma Irradiation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshiyama, Makoto
× Yoshiyama, Makoto× Okamoto, Yasuaki× Izumi, Shunsuke× Iizuka, Daisuke× Iizuka, Daisuke |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A procedure for the determination of iron in mice urine using graphite furnace atomic absorption spectrometry was developed. The mice urinary samples contain many organic compounds in the matrix, whose concentrations are approximately 20%, and the value is 30-fold higher compared to those found in human urine. Moreover, only 0.2 mL or less of urine was obtained as a sample volume per urination event. It was difficult to decompose the organic materials in the samples by wet digestion using mineral acids and oxidising agents, because of the tiny volumes. In this experiment, raw urinary samples were placed directly into the graphite tube furnace for analysis. The organic contents were simply ashed during the preheating stages. To facilitate ashing in the furnace, air was invaded from the surroundings by interrupting the stream of argon gas. Atomic absorption was measured at 248.3270 nm (wavelength for atomic absorption), with the background monitored at 247.0658 nm (wavelength for background correction). The optimised instrument operating conditions precluded the use of chemical modification technique. The analytical procedures used are quite simple, i.e. an aliquot of raw urine sample was injected directly into the graphite tube furnace and was followed by a suitable heating programme with no chemical modifier. Therefore, this method is useful for scientists who are not familiar with delicate chemical experiments. The proposed analytical method was applied as a kind of biomarker by determining iron concentrations in urinary samples of mice, which were irradiated with 4 Gy of gamma irradiation to their whole body. The time dependence of the iron concentration was determined, and the iron concentrations increased within 1 day of irradiation exposure, then decreased to ordinal values after several days. | |||||
書誌情報 |
Biological Trace Element Research 巻 191, 号 1, p. 149-158, 発行日 2018-12 |
|||||
出版者 | ||||||
出版者 | Springer | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0163-4984 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 30506323 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12011-018-1589-2 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://link.springer.com/article/10.1007/s12011-018-1589-2 |