WEKO3
アイテム
Determination of 107Pd in Pd purified by selective precipitation from spent nuclear fuel by laser ablation ICP-MS
https://repo.qst.go.jp/records/49437
https://repo.qst.go.jp/records/4943786aa9cfc-9375-450f-a88b-12d43b7493d3
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-02-18 | |||||
タイトル | ||||||
タイトル | Determination of 107Pd in Pd purified by selective precipitation from spent nuclear fuel by laser ablation ICP-MS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
浅井, 志保
× 浅井, 志保× 大畑, 昌輝× 蓬田, 匠× 佐伯, 盛久× 大場, 弘則× 半澤, 有希子× 堀田, 拓摩× Kitatsuji, Yoshihiro× 佐伯 盛久× 大場 弘則 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Determination of radiopalladium 107Pd is required to ensure radiation safety of the Pd extracted from spent nuclear fuel for recycling or disposal. We employed nanosecond laser ablation inductively coupled plasma quadrupole mass spectrometry (ns-LA-ICP-QMS) to simplify the analytical procedure of 107Pd. Pd was separated through a selective Pd precipitation reaction induced by pulsed laser irradiation that reduces Pd(II) ions to metal Pd(0). Laser ablation facilitates direct measurement of the Pd precipitates, skipping the dissolution and dilution procedure with aqua regia and HCl, which causes serious corrosion damage to the introduction system of the ICP. In the present study, 102Pd in natural Pd standard solution was used as an internal standard owing to its absence in spent nuclear fuel. Pd precipitates with diameters ranging from 0.2 μm to 0.5 μm, obtained by pulsed laser irradiation, were embedded uniformly on the surface of the centrifugal filter to form a microscopically thin and flat Pd surface. The resulting homogeneous Pd layer is suitable for obtaining a stable signal ratio of 107Pd/102Pd (<4%, 2RSD). The mass-bias-corrected ratio of 107Pd/102Pd and the amount of 107Pd were 0.163 ± 0.004 and 17.8 ± 0.6 ng, respectively, which correspond to the values obtained by solution nebulization measurement after the dissolution of identical Pd precipitates. | |||||
書誌情報 |
Analytical and Bioanalytical Chemistry 巻 411, 号 5, p. 973-983, 発行日 2018-12 |
|||||
出版者 | ||||||
出版者 | Springer | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1618-2642 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s00216-018-1527-3 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1007/s00216-018-1527-3 | |||||
関連名称 | https://doi.org/10.1007/s00216-018-1527-3 |