ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

A screening survey exercise for thyroid internal exposure from radioiodine after a nuclear accident

https://repo.qst.go.jp/records/49361
https://repo.qst.go.jp/records/49361
41775c90-bdd4-47f1-9de4-a4b40a547849
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-12-20
タイトル
タイトル A screening survey exercise for thyroid internal exposure from radioiodine after a nuclear accident
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 800353

Yajima, Kazuaki

Search repository
Kim, Eunjoo

× Kim, Eunjoo

WEKO 800354

Kim, Eunjoo

Search repository
Tani, Kotaro

× Tani, Kotaro

WEKO 800355

Tani, Kotaro

Search repository
Tatsuzaki, Hideo

× Tatsuzaki, Hideo

WEKO 800356

Tatsuzaki, Hideo

Search repository
Li, Chunsheng

× Li, Chunsheng

WEKO 800357

Li, Chunsheng

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 800358

Kurihara, Osamu

Search repository
Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 800359

en Yajima, Kazuaki

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 800360

en Eunjoo, Kim

Search repository
Tani, Kotaro

× Tani, Kotaro

WEKO 800361

en Tani, Kotaro

Search repository
Tatsuzaki, Hideo

× Tatsuzaki, Hideo

WEKO 800362

en Tatsuzaki, Hideo

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 800363

en Kurihara, Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 In the aftermath of the 2011 Fukushima nuclear disaster, a screening survey for thyroid internal exposure from intake of radioiodine was performed on 1080 children using handheld NaI(Tl) survey meters. This article presents the design and results of a practical exercise conducted to develop the skills of personnel who would be potentially engaged in such a survey. Participants of this exercise were asked to measure manikin heads in which point sources were installed under normal (~0.05 μSv h−1) and elevated (~0.5 μSv h−1) background conditions. The results demonstrated that the measurements were less dependent on the background radiation level, and the deviation of net signals obtained by the participants were within 10–20% for dose rates above 0.2 μSv h−1. This result suggests that dose rates can be reliably obtained above a provisional operational intervention level for the device, 0.5 μSv h−1 under a real nuclear accident situation.
書誌情報 Radiation Protection Dosimetry

巻 183, 号 4, p. 483-488, 発行日 2018-10
出版者
出版者 Oxford University Press.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncy175
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1093/rpd/ncy175
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:38:06.209487
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3