WEKO3
アイテム
A retrospective multicenter study of carbon-ion radiotherapy for major salivary gland carcinomas: subanalysis of J-CROS 1402 HN
https://repo.qst.go.jp/records/49324
https://repo.qst.go.jp/records/49324d12fad0a-565e-43cd-a781-694afc58a367
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-12 | |||||
タイトル | ||||||
タイトル | A retrospective multicenter study of carbon-ion radiotherapy for major salivary gland carcinomas: subanalysis of J-CROS 1402 HN | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hayashi, Kazuhiko
× Hayashi, Kazuhiko× Koto, Masashi× Demizu, Yusuke× Jun-ichi, Saitoh× Suefuji, Hiroaki× Okimoto, Tomoaki× Ohno, Tatsuya× Shioyama, Yoshiyuki× Takagi, Ryo× Ikawa, Hiroaki× Nemoto, Kenji× Nakano, Takashi× Kamada, Tadashi× the, Japan Carbon‐Ion Radiation Oncology Study Group× Hayashi, Kazuhiko× Koto, Masashi× Takagi, Ryo× Ikawa, Hiroaki× Kamada, Tadashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A retrospective multicenter study was conducted to assess the clinical outcomes of carbon-ion radiotherapy for head and neck malignancies (Japan Carbon-Ion Radiation Oncology Study Group [J-CROS] study: 1402 HN). We evaluated the safety and efficacy of carbon-ion radiotherapy in patients with major salivary gland carcinoma. Sixty-nine patients treated with carbon-ion radiotherapy at 4 Japanese institutions were analyzed. Thirty-three patients (48%) had adenoid cystic carcinomas, 10 (14%) had mucoepidermoid carcinomas, and 26 (38%) had other disease types. Three patients (4%) had T1 disease, 8 (12%) had T2, 25 (36%) had T3, and 33 (48%) had T4. The median radiation dose was 64 Gy (relative biological effectiveness) in 16 fractions. The median gross tumor volume was 27 mL. The median follow-up period was 32.7 months. The 3-year local control rate and overall survival rate were 81% and 94%, respectively. Regarding acute toxicities, 7 patients had grade 3 mucositis and 7 had grade 3 dermatitis. Regarding late toxicities, 1 patient had grade 3 dysphagia and 1 had a grade 3 brain abscess. No grade 4 or worse late reactions were observed. In conclusion, definitive carbon-ion radiotherapy was effective with acceptable toxicity for major salivary gland carcinomas. | |||||
書誌情報 |
Cancer Science 巻 109, 号 5, p. 1576-1582, 発行日 2018-04 |
|||||
出版者 | ||||||
出版者 | Wiley | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-9032 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 29493851 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1111/cas.13558 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://onlinelibrary.wiley.com/doi/full/10.1111/cas.13558 |