WEKO3
アイテム
Carbon-ion radiotherapy for locally recurrent rectal cancer: Japan Carbon-ion Radiation Oncology Study Group (J-CROS) Study 1404 Rectum.
https://repo.qst.go.jp/records/49286
https://repo.qst.go.jp/records/49286d17c7cd9-4fa7-4d3d-b826-e4f91a81603e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-11-30 | |||||
タイトル | ||||||
タイトル | Carbon-ion radiotherapy for locally recurrent rectal cancer: Japan Carbon-ion Radiation Oncology Study Group (J-CROS) Study 1404 Rectum. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Shinoto, Makoto
× Shinoto, Makoto× Yamada, Shigeru× Okamoto, Masahiko× Shioyama, Yoshiyuki× Ohno, Tatsuya× Nakano, Takashi× Nemoto, Kenji× Isozaki, Yuka× Kawashiro, Shohei× Tsuji, Hiroshi× Kamada, Tadashi× Shinoto, Makoto× Yamada, Shigeru× Okamoto, Masahiko× Shioyama, Yoshiyuki× Ohno, Tatsuya× Nakano, Takashi× Nemoto, Kenji× Isozaki, Yuka× Kawashiro, Shohei× Tsuji, Hiroshi× Kamada, Tadashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: We investigated the efficacy and safety of carbon-ion radiotherapy (C-ion RT) for locally recurrent rectal cancer (LRRC). Patients and methods: Data from patients with LRRC treated with C-ion RT from November 2003 to December 2014 at three institutions were retrospectively analyzed. The endpoints of this clinical trial were overall survival (OS), local control (LC), and acute/late toxicity. Results: A total of 224 patients’ data were collected. The prescribed dose was 70.4 Gy (relative biological effectiveness [RBE]-weighted absorbed dose) or 73.6 Gy (RBE) in 16 fractions. The median follow-up period from the initiation of C-ion RT was 62 months (range 6–169 months). The OS rates were 73% (95% confidence interval [CI], 67%–79%) at 3 years and 51% (95%CI 44%–58%) at 5 years. The LC rates were 93% (95%CI 88%–96%) at 3 years, and 88% (95%CI 82%–93%) at 5 years. Grade 3 acute toxicity was observed in three patients: gastrointestinal toxicity (n = 1) and pelvic infection (n = 2). Grade 3 late toxicity was observed in 12 patients: skin reaction (n = 2), gastrointestinal toxicity (n = 2), neuropathy (n = 1), and pelvic infection (n = 7). There was no grade 4 or 5 acute or late toxicity. Conclusions: This first multi-institutional analysis of C-ion RT for LRRC indicated relatively favorable outcomes with limited toxicities. |
|||||
書誌情報 |
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 巻 132, p. 236-240, 発行日 2018-10 |
|||||
出版者 | ||||||
出版者 | Elsevier Scientific Publishers | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0167-8140 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 30360998 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radonc.2018.10.007 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.thegreenjournal.com/article/S0167-8140(18)33519-9/abstract |