ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Influence on moisture and hydrocarbons on conversion rate of tritium in catalytic reactors of fusion-DEMO detritiation system

https://repo.qst.go.jp/records/49280
https://repo.qst.go.jp/records/49280
a4f7548a-91cb-414f-8106-d07ae9d6188f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-11-27
タイトル
タイトル Influence on moisture and hydrocarbons on conversion rate of tritium in catalytic reactors of fusion-DEMO detritiation system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 枝尾, 祐希

× 枝尾, 祐希

WEKO 497283

枝尾, 祐希

Search repository
佐藤, 克美

× 佐藤, 克美

WEKO 497284

佐藤, 克美

Search repository
岩井, 保則

× 岩井, 保則

WEKO 497285

岩井, 保則

Search repository
林, 巧

× 林, 巧

WEKO 497286

林, 巧

Search repository
枝尾 祐希

× 枝尾 祐希

WEKO 497287

en 枝尾 祐希

Search repository
佐藤 克美

× 佐藤 克美

WEKO 497288

en 佐藤 克美

Search repository
岩井 保則

× 岩井 保則

WEKO 497289

en 岩井 保則

Search repository
林 巧

× 林 巧

WEKO 497290

en 林 巧

Search repository
抄録
内容記述タイプ Abstract
内容記述 Thoughtful consideration of abnormal events such as fire is required to design and qualify a detritiation system (DS) of a nuclear fusion facility. Since conversion of tritium to tritiated vapor over catalyst is the key process of the DS, it is indispensable to evaluate the effect of excess moisture and hydrocarbons produced by combustion of cables on tritium conversion rate considering fire events. We conducted demonstration tests on tritium conversion under the following representative conditions, (I) leakage of tritium; (II) leakage of tritium plus moisture; (III) leakage of tritium plus hydrocarbons. Detritiation behavior in the simulated room was assessed, and the amount of catalyst to fulfill the requirement on tritium conversion rate was evaluated. The dominant parameters for detritiation are the concentration of hydrogen in air and catalyst temperature. The tritium in the simulated room was decreased for condition (I) following ventilation theory. An initial reduction in conversion rate was measured for condition (II). To recover the reduction smoothly, it is suggested to optimize the power of preheater. An increase in catalyst temperature by heat of reaction of hydrocarbon combustion was evaluated for condition (III). The heat balance of catalytic reactor is a point to be carefully investigated to avoid runaway of catalyst temperature.
書誌情報 Journal of Nuclear Science and Technology

巻 54, 号 7, p. 761-768, 発行日 2018-11
出版者
出版者 Taylor & Francis
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
DOI
識別子タイプ DOI
関連識別子 10.1080/00223131.2017.1315970
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1080/00223131.2017.1315970
関連名称 https://doi.org/10.1080/00223131.2017.1315970
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:20:21.200612
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3