Multicentre analysis of PET SUV using vendor-neutral software: the Japanese Harmonization Technology (J-Hart) study

https://repo.qst.go.jp/records/49247
https://repo.qst.go.jp/records/49247
b0f044e7-a145-4710-931e-da13ab6af66b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-09-04
タイトル
タイトル Multicentre analysis of PET SUV using vendor-neutral software: the Japanese Harmonization Technology (J-Hart) study
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsutsui, Yuji

× Tsutsui, Yuji

WEKO 871868

Tsutsui, Yuji

Search repository
Daisaki, Hiromitsu

× Daisaki, Hiromitsu

WEKO 871869

Daisaki, Hiromitsu

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 871870

Akamatsu, Go

Search repository
Umeda, Takuro

× Umeda, Takuro

WEKO 871871

Umeda, Takuro

Search repository
Ogawa, Matsuyoshi

× Ogawa, Matsuyoshi

WEKO 871872

Ogawa, Matsuyoshi

Search repository
Kajiwara, Hironori

× Kajiwara, Hironori

WEKO 871873

Kajiwara, Hironori

Search repository
Kawase, Shigeto

× Kawase, Shigeto

WEKO 871874

Kawase, Shigeto

Search repository
Sakurai, Minoru

× Sakurai, Minoru

WEKO 871875

Sakurai, Minoru

Search repository
Nishida, Hiroyuki

× Nishida, Hiroyuki

WEKO 871876

Nishida, Hiroyuki

Search repository
Magota, Keiichi

× Magota, Keiichi

WEKO 871877

Magota, Keiichi

Search repository
Mori, Kazuaki

× Mori, Kazuaki

WEKO 871878

Mori, Kazuaki

Search repository
Sasaki, Masayuki

× Sasaki, Masayuki

WEKO 871879

Sasaki, Masayuki

Search repository
J-Hart, study group

× J-Hart, study group

WEKO 871880

J-Hart, study group

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 871881

en Akamatsu, Go

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background: Recent developments in hardware and software for PET technologies have resulted in wide variations in basic performance. Multicentre studies require a standard imaging protocol and SUV harmonization to reduce inter- and intra-scanner variability in the SUV. The Japanese standardised uptake value (SUV) Harmonization Technology (J-Hart) study aimed to determine the applicability of vendor-neutral software on the SUV derived from positron emission tomography (PET) images. The effects of SUV harmonization were evaluated based on the reproducibility of several scanners and the repeatability of an individual scanner. Images were acquired from 12 PET scanners at nine institutions. PET images were acquired over a period of 30 min from a National Electrical Manufacturers Association (NEMA) International Electrotechnical Commission (IEC) body phantom containing six spheres of different diameters and an 18F solution with a background activity of 2.65 kBq/mL and a sphere-to-background ratio of 4. The images were reconstructed to determine parameters for harmonization and to evaluate reproducibility. PET images with 2-min acquisition × 15 contiguous frames were reconstructed to evaluate repeatability. Various Gaussian filters (GFs) with full-width at half maximum (FWHM) values ranging from 1 to 15 mm in 1-mm increments were also applied using vendor-neutral software. The SUVmax of spheres was compared with the reference range proposed by the Japanese Society of Nuclear Medicine (JSNM) and the digital reference object (DRO) of the NEMA phantom. The coefficient of variation (CV) of the SUVmax determined using 12 PET scanners (CVrepro) was measured to evaluate reproducibility. The CV of the SUVmax determined from 15 frames (CVrepeat) per PET scanner was measured to determine repeatability. Results: Three PET scanners did not require an additional GF for harmonization, whereas the other nine required additional FWHM values of GF ranging from 5 to 9 mm. The pre- and post-harmonization CVrepro of six spheres were (means ± SD) 9.45% ± 4.69% (range, 3.83–15.3%) and 6.05% ± 3.61% (range, 2.30–10.7%), respectively. Harmonization significantly improved reproducibility of PET SUVmax (P = 0.0055). The pre- and post-harmonization CVrepeat of nine scanners were (means ± SD) 6.59% ± 1.29% (range, 5.00–8.98%) and 4.88% ± 1.64% (range, 2.65–6.72%), respectively. Harmonization also significantly improved the repeatability of PET SUVmax (P < 0.0001). Conclusions: Harmonizing SUV using vendor-neutral software produced SUVmax for 12 scanners that fell within the JSNM reference range of a NEMA body phantom and improved SUVmax reproducibility and repeatability.
書誌情報 EJNMMI research

巻 8, 発行日 2018-08
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 2191-219X
PubMed番号
識別子タイプ PMID
関連識別子 30128776
DOI
識別子タイプ DOI
関連識別子 10.1186/s13550-018-0438-9
関連サイト
識別子タイプ URI
関連識別子 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6102169/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:06:33.760758
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3