ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development of a stochastic biokinetic method and its application to internal dose estimation for insoluble cesium-bearing particles

https://repo.qst.go.jp/records/49218
https://repo.qst.go.jp/records/49218
a3882b7e-f004-4690-bd95-94290e739f0a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-10-26
タイトル
タイトル Development of a stochastic biokinetic method and its application to internal dose estimation for insoluble cesium-bearing particles
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Manab, Kentaro

× Manab, Kentaro

WEKO 757980

Manab, Kentaro

Search repository
Matsumoto, Masaki

× Matsumoto, Masaki

WEKO 757981

Matsumoto, Masaki

Search repository
Matsumoto, Masaki

× Matsumoto, Masaki

WEKO 757982

en Matsumoto, Masaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Spherical cesium-bearing particles were found around the Fukushima Daiichi Nuclear Power Plant after its accident. These particles are insoluble with high specific activities. If such a particle is incorporated into the body, it is expected that the radioactive cesium contained in the particle will move as a single particulate material without being distributed throughout the body. Consequently, internal doses vary depending on the pathway of the particle in the body. Therefore, general deterministic methods for dose estimation are not applicable to the intake of small number of cesium-bearing particles. In this study, a Monte Carlo method was developed to evaluate a probability density function of internal doses for inhalation of a particulate material. In addition, a biokinetic model was constructed to consider the insolubility of the particles. Probability density functions of committed equivalent and effective doses were estimated using the constructed biokinetic model with the developed omputation method. As a result, the uncertainty of the doses was very large for single particle inhalation. However, it was observed that this uncertainty decreased with increasing number of simultaneously inhaled particles. On the other hand, the consideration about the insolubility made the doses somewhat higher than those based on the general cesium model.
書誌情報 JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY

巻 56, 号 1, p. 78-86, 発行日 2018-10
出版者
出版者 TAYLOR & FRAVCIS LTD.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
DOI
識別子タイプ DOI
関連識別子 10.1080/00223131.2018.1523756
関連サイト
識別子タイプ URI
関連識別子 https://www.tandfonline.com/doi/full/10.1080/00223131.2018.1523756
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:53:43.075983
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3