Determination of uranium in immersion liquid of demolition waste using total reflection X-ray fluorescence analysis

https://repo.qst.go.jp/records/49203
https://repo.qst.go.jp/records/49203
7417ab3e-1e63-4f75-b741-081801df4b03
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-07-20
タイトル
タイトル Determination of uranium in immersion liquid of demolition waste using total reflection X-ray fluorescence analysis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsuyama, Tsugufumi

× Matsuyama, Tsugufumi

WEKO 734129

Matsuyama, Tsugufumi

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 734130

Izumoto, Yukie

Search repository
Ishii, Kota

× Ishii, Kota

WEKO 734131

Ishii, Kota

Search repository
Sakai, Yasuhiro

× Sakai, Yasuhiro

WEKO 734132

Sakai, Yasuhiro

Search repository
Yoshii, Hiroshi

× Yoshii, Hiroshi

WEKO 734133

Yoshii, Hiroshi

Search repository
Matsuyama, Tsugufumi

× Matsuyama, Tsugufumi

WEKO 734134

en Matsuyama, Tsugufumi

Search repository
Izumoto, Yukie

× Izumoto, Yukie

WEKO 734135

en Izumoto, Yukie

Search repository
Ishii, Kota

× Ishii, Kota

WEKO 734136

en Ishii, Kota

Search repository
Yoshii, Hiroshi

× Yoshii, Hiroshi

WEKO 734137

en Yoshii, Hiroshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 In this study, we proposed a novel methodology based on total reflection X-ray fluorescence (TXRF) analysis for rapid evaluation of uranium radioactivity concentration in water samples, which will be found in the decommissioning field of Fukushima Daiichi Nuclear Power Plant containing various impurities. Sample solutions were prepared by mixing a multi-element standard solution containing uranium and thorium with an immersion liquid of the demolition debris in order to examine the effect of components of the demolition debris. An indium standard solution was added to the samples as an internal standard. Since the Rb Kα peak overlapped with the U Lα and Th Lα peaks, Gaussian fitting was performed to determine the net intensity of the U Lα peak. Moreover, due to the largely different contents of uranium and rubidium, reducing the number of fitting parameter made the Gaussian fitting easier. To determine the widths of the peaks, long-time TXRF measurement of the standard solutions for each element was performed. In the Gaussian fitting, only the peak intensities were considered as fitting parameters because the peak widths and peak energies could be fixed. The relative intensity of the U Lα peak was calculated as the net intensity of the U Lα peak normalized by that of the In Kα peak. The relative intensity was directly proportional to the uranium concentration. The estimated minimum detection limit of uranium with a measurement time of 15 min was significantly lower than the effluent standard value for uranium concentration in drainage water as defined by the Japanese Water Pollution Prevention Law, 20 mBq/cm3. All in all, we believe that this method will be useful in determining the uranium concentration in drainage water in the decommissioning field of Fukushima Daiichi Nuclear Power Plant.
書誌情報 Spectrochimica Acta Part B: Atomic Spectroscopy

巻 149, p. 35-41, 発行日 2018-07
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0584-8547
DOI
識別子タイプ DOI
関連識別子 10.1016/j.sab.2018.07.010
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0584854718300648
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:06:01.654619
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3