WEKO3
アイテム
Evaluation of total-reflection X-ray fluorescence measurements for the prospective determination of uranium in the decommissioning of the Fukushima Daiichi Nuclear Power Plant reactor
https://repo.qst.go.jp/records/49202
https://repo.qst.go.jp/records/49202e945c7bd-f142-42e3-bd42-2cba12bcf9f5
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-07-20 | |||||
タイトル | ||||||
タイトル | Evaluation of total-reflection X-ray fluorescence measurements for the prospective determination of uranium in the decommissioning of the Fukushima Daiichi Nuclear Power Plant reactor | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshii, Hiroshi
× Yoshii, Hiroshi× Izumoto, Yukie× Matsuyama, Tsugufumi× Ishii, Kota× Sakai, Yasuhiro× Yoshii, Hiroshi× Izumoto, Yukie× Matsuyama, Tsugufumi× Ishii, Kota |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Owing to the strong earthquake and subsequent tsunami in March 2011, the Fukushima Daiichi Nuclear Power Plant was exceedingly damaged and is currently under decommissioning. Herein, we propose a methodology to evaluate the uranium concentration in the drainage water from the decommissioning field. Model sample solutions were prepared by mixing multi-element standard solutions containing uranium with an immersion liquid containing demolition debris. A very small amount (10 μL) of the sample solutions was dropped onto a quartz optical flat directory with or without a chromatography resin separation. The total-reflection X-ray fluorescence (TXRF) spectrometry measurement was performed using a portable device. These measurements showed an overlap of the Rb Kα and U Lα peaks in the TXRF spectrum of the sample solution prepared without chromatography resin separation. By contrast, no overlap was observed in the TXRF spectrum of the sample solution after the separation using a chromatography resin. When the drainage water is composed of 0.04% U-234, 5% U-235, and 94.96% U-238, the measurement times in both methods (i.e., with and without pretreatment) required to attain detection limits lower than the effluent standard value are 15 and 5 min, respectively. Additionally, the detection limits, analysis times, required sample volumes, and procedures of the two methods are compared. | |||||
書誌情報 |
Spectrochimica Acta Part B: Atomic Spectroscopy 巻 148, p. 183-187, 発行日 2018-07 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0584-8547 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.sab.2018.07.004 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0584854718300636#! |