ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development of in situ synchrotron X-ray total scattering setup under pressurized hydrogen gas

https://repo.qst.go.jp/records/49160
https://repo.qst.go.jp/records/49160
de3c145a-15c3-4607-a59d-c7b40f4ed538
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-09-05
タイトル
タイトル Development of in situ synchrotron X-ray total scattering setup under pressurized hydrogen gas
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sakaki, Kouji

× Sakaki, Kouji

WEKO 496008

Sakaki, Kouji

Search repository
Kim, Hyunjeong

× Kim, Hyunjeong

WEKO 496009

Kim, Hyunjeong

Search repository
Machida, Akihiko

× Machida, Akihiko

WEKO 496010

Machida, Akihiko

Search repository
Watanuki, Tetsu

× Watanuki, Tetsu

WEKO 496011

Watanuki, Tetsu

Search repository
Katayama, Yoshinori

× Katayama, Yoshinori

WEKO 496012

Katayama, Yoshinori

Search repository
Nakamura, Yumiko

× Nakamura, Yumiko

WEKO 496013

Nakamura, Yumiko

Search repository
町田 晃彦

× 町田 晃彦

WEKO 496014

en 町田 晃彦

Search repository
綿貫 徹

× 綿貫 徹

WEKO 496015

en 綿貫 徹

Search repository
片山 芳則

× 片山 芳則

WEKO 496016

en 片山 芳則

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have developed an in situ gas‐loading sample holder for synchrotron X‐ray total scattering experiments, particularly for hydrogen storage materials, designed to collect diffraction and pair distribution function (PDF) data under pressurized hydrogen gas. A polyimide capillary with a diameter and thickness of 1.4 and 0.06 mm, respectively, connected with commercially available fittings was used as an in situ sample holder. Gas-leakage tests confirmed that this sample holder allows 3 MPa of hydrogen gas pressure and 393 K to be achieved without leakage. Using the developed in situ sample holder, significant background and Bragg peaks from the sample holder were not observed in the X‐ray total scattering patterns and their signal‐to‐noise ratios were sufficiently good. The results of Rietveld and PDF refinements of Ni powder are consistent with those obtained using a polyimide capillary (1.0 mm diameter and 0.04 mm thickness) that has been used for ex situ experiments. In addition, in situ synchrotron X‐ray total scattering experiments under pressurized hydrogen gas up to 1 MPa were successfully demonstrated for LaNi4.6Cu.
書誌情報 Journal of Applied Crystallography

巻 51, 号 3, p. 796-801, 発行日 2018-05
出版者
出版者 Wiley Online Library
ISSN
収録物識別子タイプ ISSN
収録物識別子 1600-5767
DOI
識別子タイプ DOI
関連識別子 10.1107/S1600576718005101
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:20:55.516641
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3