WEKO3
アイテム
Radial electron fluence around ion tracks as a new physical parameter for the detection threshold of PADC using Geant4-DNA toolkit
https://repo.qst.go.jp/records/49157
https://repo.qst.go.jp/records/4915782c3576a-eb03-4e8b-bde5-4713fcfc752e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-09-03 | |||||
タイトル | ||||||
タイトル | Radial electron fluence around ion tracks as a new physical parameter for the detection threshold of PADC using Geant4-DNA toolkit | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kusumoto, Tamon
× Kusumoto, Tamon× EL Bitar, Ziad× Okada, Shogo× Gillet, Pierre× Arbor, Nicolas× Kanasaki, Masato× Mori, Yutaka× Oda, Keiji× Abdel-Mjid, Nourreddine× Kurashige, Hisaya× Fromm, Michel× Cloutier, Pierre× D. Bass, Andrew× Léon, Sanche× Kodaira, Satoshi× Rémi, Barillon× Yamauchi, Tomoya× Tamon, Kusumoto× Satoshi, Kodaira |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The detection threshold of poly(allyl dyglycol carbonate), PADC, for C ions is determined as 55 eV/nm in stopping power, which is significantly higher than that for proton and He ions. The stopping power is not a universal parameter for expressing the detection threshold of PADC. A new physical parameter of Radial Electron Fluence around Ion Tracks, REFIT, is proposed to describe the detection threshold of PADC. It is defined as the number density of electrons passing through the surface of a cylinder of a certain radius that is co-axial with the trajectory. Furthermore, preliminary calculations are presently being performed using the Monte Carlo simulation code of Geant4-DNA. The values of the REFIT at the detection thresholds for each ion are of the same order. Several issues affecting implementation of the REFIT paramter are discussed. These include the effects of impact parameter relating to the initial locations of secondary electrons, the effects of electron attachment below the cut off energy of 7.4 eV and the necessity of a more physically realistic medium than water for Monte Carlo simultaions. | |||||
書誌情報 |
Radiation Measurements 巻 118, p. 50-53, 発行日 2018-09 |
|||||
出版者 | ||||||
出版者 | ELSEVIER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1350-4487 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.radmeas.2018.08.015 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ac.els-cdn.com/S1350448718301197/1-s2.0-S1350448718301197-main.pdf?_tid=b763d8c0-90bc-4c6b-a606-b32b471db43c&acdnat=1535957155_650e57158000919e2b6c90d231a920d7 |