Improving Accuracy of Noninterceptive Current Measurement for Use in IFMIF/EVEDA Accelerator

https://repo.qst.go.jp/records/49155
https://repo.qst.go.jp/records/49155
4689fd8e-4af2-40da-8518-2fcf63f4d157
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-08-31
タイトル
タイトル Improving Accuracy of Noninterceptive Current Measurement for Use in IFMIF/EVEDA Accelerator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 平田, 洋介

× 平田, 洋介

WEKO 800726

平田, 洋介

Search repository
春日井, 敦

× 春日井, 敦

WEKO 800727

春日井, 敦

Search repository
Nishiyama, Koichi

× Nishiyama, Koichi

WEKO 800728

Nishiyama, Koichi

Search repository
Marqueta, Alvaro

× Marqueta, Alvaro

WEKO 800729

Marqueta, Alvaro

Search repository
Hirata, Yosuke

× Hirata, Yosuke

WEKO 800730

en Hirata, Yosuke

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 800731

en Kasugai, Atsushi

Search repository
Nishiyama, Koichi

× Nishiyama, Koichi

WEKO 800732

en Nishiyama, Koichi

Search repository
Marqueta, Alvaro

× Marqueta, Alvaro

WEKO 800733

en Marqueta, Alvaro

Search repository
抄録
内容記述タイプ Abstract
内容記述 Current transformers (CTs) (ACCT/DCCT) are used as noninterceptive means of beam current measurement in the IFMIF/EVEDA accelerator. However, current measurement using CTs for long pulses with 100 ms or longer such problems as droops are apparent. This is due to the fact that this measurement is based on the current induction through transformers and is considered inevitable. We propose a method for retrieving the beam currents from the ACCT output waveforms using an experimentally obtained transfer function. This method has several advantages. The transfer function is easy to obtain from simple experiments with a function generator and an oscilloscope other than the ACCT and an amplifier, and the effects of stray capacitance, inductance, and magnetic materials nearby are inherently included in the transfer function. Square waveforms with different pulselengths are used to numerically obtain the forward and backward transfer functions, and this method for current waveform retrieval was validated. It was confirmed in experiments that square waveforms with lengths from 100 ms to 1.3 s could be retrieved without droops from the ACCT output.
書誌情報 IEEE Transactions on Plasma Science

巻 46, 号 6, p. 2272-2276, 発行日 2018-06
出版者
出版者 IEEE
ISSN
収録物識別子タイプ ISSN
収録物識別子 0093-3813
DOI
識別子タイプ DOI
関連識別子 10.1109/TPS.2018.2827038
関連サイト
識別子タイプ URI
関連識別子 https://ieeexplore.ieee.org/document/8352111/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:37:55.795533
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3