  1. 原著論文

Femoral neck fracture and central migration of the artificial femoral head after carbon ion radiotherapy for chondrosarcoma in the pelvis

https://repo.qst.go.jp/records/49121
https://repo.qst.go.jp/records/49121
c44c9783-d348-48b0-85f7-5fa1c25faa6d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-08-01
タイトル
タイトル Femoral neck fracture and central migration of the artificial femoral head after carbon ion radiotherapy for chondrosarcoma in the pelvis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 N, Sumiyoshi

× N, Sumiyoshi

WEKO 797316

N, Sumiyoshi

Search repository
T, Torigoe

× T, Torigoe

WEKO 797317

T, Torigoe

Search repository
K, Maezawa

× K, Maezawa

WEKO 797318

K, Maezawa

Search repository
Y, Narushima

× Y, Narushima

WEKO 797319

Y, Narushima

Search repository
Y, Maruyama

× Y, Maruyama

WEKO 797320

Y, Maruyama

Search repository
K, Kaneko

× K, Kaneko

WEKO 797321

K, Kaneko

Search repository
Imai, Reiko

× Imai, Reiko

WEKO 797322

Imai, Reiko

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 797323

Kamada, Tadashi

Search repository
Imai, Reiko

× Imai, Reiko

WEKO 797324

en Imai, Reiko

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 797325

en Kamada, Tadashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Chondrosarcoma is refractory to chemotherapy or radiotherapy due to its slow progression. Consequently, a wide en bloc excision is thought to be the only curative treatment for intermediate and high-grade lesions [1]. In comparison to X-ray beams, carbon ion beams offer a better dose distribution, having a higher physical selectivity, Bragg peak and relative biological effectiveness. Carbon ion radiotherapy (CIRT) has recently been introduced as a therapeutic option in cases of chondrosarcoma in which a wide en bloc excision is not possible. Although this is a new treatment and it is not yet available in most countries, a few cases in which femoral neck fractures occurred secondary to CIRT have already been reported in the literature [2,3,11]. We herein present the case of a
patient with pelvic chondrosarcoma who was treated with CIRT, in whom a femoral neck fracture developed with subsequent central migration of the rtificial femoral head. Revision surgery, which consisted of total hip rthroplasty with allo- and auto-bone grafts and a KT plate, was successfully performed to treat the complications that were seen in the present case.
書誌情報 Journal of Orthopaedic Science

巻 23, 号 2, p. 424-429, 発行日 2016-08
出版者
出版者 Elsevier B.V.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0949-2658
PubMed番号
識別子タイプ PMID
関連識別子 27531572
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jos.2016.07.014
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.jos.2016.07.014
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:39:30.378444
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3