WEKO3
アイテム
Femoral neck fracture and central migration of the artificial femoral head after carbon ion radiotherapy for chondrosarcoma in the pelvis
https://repo.qst.go.jp/records/49121
https://repo.qst.go.jp/records/49121c44c9783-d348-48b0-85f7-5fa1c25faa6d
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2018-08-01 | |||||
| タイトル | ||||||
| タイトル | Femoral neck fracture and central migration of the artificial femoral head after carbon ion radiotherapy for chondrosarcoma in the pelvis | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
N, Sumiyoshi
× N, Sumiyoshi× T, Torigoe× K, Maezawa× Y, Narushima× Y, Maruyama× K, Kaneko× Imai, Reiko× Kamada, Tadashi× Imai, Reiko× Kamada, Tadashi |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Chondrosarcoma is refractory to chemotherapy or radiotherapy due to its slow progression. Consequently, a wide en bloc excision is thought to be the only curative treatment for intermediate and high-grade lesions [1]. In comparison to X-ray beams, carbon ion beams offer a better dose distribution, having a higher physical selectivity, Bragg peak and relative biological effectiveness. Carbon ion radiotherapy (CIRT) has recently been introduced as a therapeutic option in cases of chondrosarcoma in which a wide en bloc excision is not possible. Although this is a new treatment and it is not yet available in most countries, a few cases in which femoral neck fractures occurred secondary to CIRT have already been reported in the literature [2,3,11]. We herein present the case of a patient with pelvic chondrosarcoma who was treated with CIRT, in whom a femoral neck fracture developed with subsequent central migration of the rtificial femoral head. Revision surgery, which consisted of total hip rthroplasty with allo- and auto-bone grafts and a KT plate, was successfully performed to treat the complications that were seen in the present case. |
|||||
| 書誌情報 |
Journal of Orthopaedic Science 巻 23, 号 2, p. 424-429, 発行日 2016-08 |
|||||
| 出版者 | ||||||
| 出版者 | Elsevier B.V. | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0949-2658 | |||||
| PubMed番号 | ||||||
| 識別子タイプ | PMID | |||||
| 関連識別子 | 27531572 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.jos.2016.07.014 | |||||
| 関連サイト | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | https://doi.org/10.1016/j.jos.2016.07.014 | |||||