ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy with a passive beam: Organ doses in prostate cancer treatment

https://repo.qst.go.jp/records/49097
https://repo.qst.go.jp/records/49097
da914a3e-2080-4694-af00-c77889749849
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-04-25
タイトル
タイトル Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy with a passive beam: Organ doses in prostate cancer treatment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 米内, 俊祐

× 米内, 俊祐

WEKO 747570

米内, 俊祐

Search repository
松藤, 成弘

× 松藤, 成弘

WEKO 747571

松藤, 成弘

Search repository
赤羽, 恵一

× 赤羽, 恵一

WEKO 747572

赤羽, 恵一

Search repository
Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 747573

en Yonai, Shunsuke

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 747574

en Matsufuji, Naruhiro

Search repository
Akahane, Keiichi

× Akahane, Keiichi

WEKO 747575

en Akahane, Keiichi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
The aim of this work was to estimate typical dose equivalents to out-of-field organs during carbon-ion radiotherapy (CIRT) with a passive beam for prostate cancer treatment. Additionally, sensitivity analyses of organ doses for various beam parameters and phantom sizes were performed.

Methods
Because the CIRT out-of-field dose depends on the beam parameters, the typical values of those parameters were determined from statistical data on the target properties of patients who received CIRT at the Heavy-Ion Medical Accelerator in Chiba (HIMAC). Using these typical beam-parameter values, out-of-field organ dose equivalents during CIRT for typical prostate treatment were estimated by Monte Carlo simulations using the Particle and Heavy-Ion Transport Code System (PHITS) and the ICRP reference phantom.

Results
The results showed that the dose decreased with distance from the target, ranging from 116 mSv in the testes to 7 mSv in the brain. The organ dose equivalents per treatment dose were lower than those either in 6-MV intensity-modulated radiotherapy or in brachytherapy with an Ir-192 source for organs within 40 cm of the target. Sensitivity analyses established that the differences from typical values were within ∼30% for all organs, except the sigmoid colon.

Conclusions
The typical out-of-field organ dose equivalents during passive-beam CIRT were shown. The low sensitivity of the dose equivalent in organs farther than 20 cm from the target indicated that individual dose assessments required for retrospective epidemiological studies may be limited to organs around the target in cases of passive-beam CIRT for prostate cancer.
書誌情報 Physica Medica

巻 51, p. 48-55, 発行日 2018-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1120-1797
DOI
識別子タイプ DOI
関連識別子 10.1016/j.ejmp.2018.04.391
関連サイト
識別子タイプ URI
関連識別子 https://www.physicamedica.com/article/S1120-1797(18)30450-2/abstract
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:57:06.245712
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3