ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Source of luminescence of water lower energy than the Cerenkov-light threshold during irradiation of carbon-ion

https://repo.qst.go.jp/records/49088
https://repo.qst.go.jp/records/49088
07474f86-2417-45f6-b0b9-4aee346311ed
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-06-25
タイトル
タイトル Source of luminescence of water lower energy than the Cerenkov-light threshold during irradiation of carbon-ion
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamamoto, (Nagoya Univ.) Seiichi

× Yamamoto, (Nagoya Univ.) Seiichi

WEKO 495239

Yamamoto, (Nagoya Univ.) Seiichi

Search repository
Akagi, (Hyogo Ion Beam Medical Center) Takashi

× Akagi, (Hyogo Ion Beam Medical Center) Takashi

WEKO 495240

Akagi, (Hyogo Ion Beam Medical Center) Takashi

Search repository
Yamashita, (Hyogo Ion Beam Medical Center) Tomohiro

× Yamashita, (Hyogo Ion Beam Medical Center) Tomohiro

WEKO 495241

Yamashita, (Hyogo Ion Beam Medical Center) Tomohiro

Search repository
Toivonen, (Tampere University of Technology) Juha

× Toivonen, (Tampere University of Technology) Juha

WEKO 495242

Toivonen, (Tampere University of Technology) Juha

Search repository
Yamaguchi, Mitsutaka

× Yamaguchi, Mitsutaka

WEKO 495243

Yamaguchi, Mitsutaka

Search repository
Komori, (Nagoya Univ.) Masataka

× Komori, (Nagoya Univ.) Masataka

WEKO 495244

Komori, (Nagoya Univ.) Masataka

Search repository
Kawachi, Naoki

× Kawachi, Naoki

WEKO 495245

Kawachi, Naoki

Search repository
山口 充孝

× 山口 充孝

WEKO 495246

en 山口 充孝

Search repository
河地 有木

× 河地 有木

WEKO 495247

en 河地 有木

Search repository
抄録
内容記述タイプ Abstract
内容記述 Although luminescence of water during irradiations of proton and carbon-ion lower energy than the Cerenkov-light threshold were found recently, the sources of the luminescence were not yet obvious. To estimate the sources of the luminescence, we measured the light spectrum of the luminescence of water during carbon-ion irradiations and estimated the sources of the luminescence. Using an ultraviolet (UV) light sensitive charge coupled device (CCD) camera, we measured the luminescence images of water during carbon-ion beam irradiations by changing optical filters, derived the light spectra of the luminescence of water and compared with the calculated results. The intensity of the measured light spectrum of the luminescence of water at the Bragg peak region was decreased as the wavelength of light proportional to ~ λ to the -2.0th power where λ is the wavelength of the light, indicating the source of the luminescence of water can be electromagnetic pulse produced by the dipole displacement inside the water molecules. In the shallow part of the water prior to the Bragg peak, where the Cerenkov-light is included, the spectrum showed steeper curve that is proportional to ~ λ to the -2.6th power, which was similar to the calculated spectrum of Cerenkov-light including the refractive index changes of water with the wavelength of light. From these results, the luminescence of water is thought to be mainly come from electromagnetic pulse produced by the dipole displacement inside the water molecules.
書誌情報 Journal of Physics Communications

巻 2, p. 065010-1-9, 発行日 2018-06
出版者
出版者 IOP Science
ISSN
収録物識別子タイプ ISSN
収録物識別子 2399-6528
DOI
識別子タイプ DOI
関連識別子 10.1088/2399-6528/aaca28
関連サイト
識別子タイプ URI
関連識別子 http://iopscience.iop.org/article/10.1088/2399-6528/aaca28/meta
関連名称 http://iopscience.iop.org/article/10.1088/2399-6528/aaca28/meta
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:14.437748
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3