WEKO3
アイテム
Cerebral serotonin transporter measurements with [11C]DASB: A review on acquisition and preprocessing across 21 PET centres.
https://repo.qst.go.jp/records/49081
https://repo.qst.go.jp/records/49081d2227573-ff5a-43e7-9e0e-8e6ee471fa1d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-06-18 | |||||
タイトル | ||||||
タイトル | Cerebral serotonin transporter measurements with [11C]DASB: A review on acquisition and preprocessing across 21 PET centres. | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Martin, Nørgaard
× Martin, Nørgaard× Ganz, Melanie× Svarer, Claus× Feng, Ling× Ichise, Masanori× Lanzenberger, Rupert× Lubberink, Mark× V Parsey, Ramin× Politis, Marios× A Rabiner, Eugenii× Slifstein, Mark× Sossi, Vesna× Suhara, Tetsuya× S Talbot, Peter× Turkheimer, Federico× C Strother, Stephen× M Knudsen, Gitte× Ichise, Masanori× Suhara, Tetsuya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Positron Emission Tomography (PET) imaging has become a prominent tool to capture the spatiotemporal distribution of neurotransmitters and receptors in the brain. The outcome of a PET study can, however, potentially be obscured by suboptimal and/or inconsistent choices made in complex processing pipelines required to reach a quantitative estimate of radioligand binding. Variations in subject selection, experimental design, data acquisition, preprocessing, and statistical analysis may lead to different outcomes and neurobiological interpretations. We here review the approaches used in 105 original research articles published by 21 different PET centres, using the tracer [11C]DASB for quantification of cerebral serotonin transporter binding, as an exemplary case. We highlight and quantify the impact of the remarkable variety of ways in which researchers are currently conducting their studies, while implicitly expecting generalizable results across research groups. Our review provides evidence that the foundation for a given choice of a preprocessing pipeline seems to be an overlooked aspect in modern PET neuroscience. Furthermore, we believe that a thorough testing of pipeline performance is necessary to produce reproducible research outcomes, avoiding biased results and allowing for better understanding of human brain function | |||||
書誌情報 |
Journal of Cerebral Blood Flow & Metabolism 巻 39, 号 2, p. 210-222, 発行日 2018-04 |
|||||
出版者 | ||||||
出版者 | SAGE Journals | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0271-678X | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 29651896 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1177/0271678X18770107 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://journals.sagepub.com/doi/full/10.1177/0271678X18770107 |