Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan

https://repo.qst.go.jp/records/49067
https://repo.qst.go.jp/records/49067
9d339d6a-e05f-4320-8285-ff05dfe41821
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-02-26
タイトル
タイトル Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 757924

Kanematsu, Nobuyuki

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 757925

Matsufuji, Naruhiro

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 757926

Inaniwa, Taku

Search repository
Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 757927

en Kanematsu, Nobuyuki

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 757928

en Matsufuji, Naruhiro

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 757929

en Inaniwa, Taku

Search repository
抄録
内容記述タイプ Abstract
内容記述 A treatment of carbon-ion radiotherapy (CIRT) is generally evaluated using the dose weighted by relative biological effectiveness (RBE) while ignoring the radiation quality varying in the patient. In this study, we have developed a method of estimating linear energy transfer (LET) from the RBE in an archived treatment plan to represent the radiation quality of the treatment. The LET in a beam database was associated with the RBE by two fitting functions per energy, one for the spread-out Bragg peak (SOBP) and the other for shallower depths, to be differentiated by RBE per energy per modulation. The estimated LET was generally consistent with the original calculation within a few keV/μm, except for the overkill region near the distal end of SOBP. The knowledge of experimental radiobiology can thereby be associated with CIRT treatments through LET, which will potentially contribute to deeper understanding of clinical radiobiology and further optimization of CIRT.
書誌情報 Radiological Physics and Technology

巻 11, 号 2, p. 242-247, 発行日 2018-02
出版者
出版者 Springer Singapore
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
PubMed番号
識別子タイプ PMID
関連識別子 29470773
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-018-0444-7
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1007/s12194-018-0444-7
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:53:44.504985
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3