ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development of radioiodine labeled acetaminophen for specific, high-contrast imaging of malignant melanoma

https://repo.qst.go.jp/records/49051
https://repo.qst.go.jp/records/49051
e4a38749-2f62-4ff3-85d8-f554bff10266
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-18
タイトル
タイトル Development of radioiodine labeled acetaminophen for specific, high-contrast imaging of malignant melanoma
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Jing, Zhu Wen

× Jing, Zhu Wen

WEKO 494751

Jing, Zhu Wen

Search repository
Kobayashi, Masato

× Kobayashi, Masato

WEKO 494752

Kobayashi, Masato

Search repository
Yamada, Kohei

× Yamada, Kohei

WEKO 494753

Yamada, Kohei

Search repository
Nishi, Kodai

× Nishi, Kodai

WEKO 494754

Nishi, Kodai

Search repository
Takahashi, Kotaro

× Takahashi, Kotaro

WEKO 494755

Takahashi, Kotaro

Search repository
Mizutani, Asuka

× Mizutani, Asuka

WEKO 494756

Mizutani, Asuka

Search repository
Nishii, Ryuichi

× Nishii, Ryuichi

WEKO 494757

Nishii, Ryuichi

Search repository
G., Flores II Leo

× G., Flores II Leo

WEKO 494758

G., Flores II Leo

Search repository
Shikano, Naoto

× Shikano, Naoto

WEKO 494759

Shikano, Naoto

Search repository
Kunishima, Munetaka

× Kunishima, Munetaka

WEKO 494760

Kunishima, Munetaka

Search repository
Kawai, Keiichi

× Kawai, Keiichi

WEKO 494761

Kawai, Keiichi

Search repository
西井 龍一

× 西井 龍一

WEKO 494762

en 西井 龍一

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract
Introduction
Due to its poor prognosis, specific imaging for early detection of malignant melanoma is strongly desired. Although radioiodine-labeled 4-hydroxyphenylcysteamine, which we previously developed, has good affinity for tyrosinase, an enzyme in the melanin metabolic pathway, image contrast of the melanoma:organ ratios is not sufficiently high for detection of primary melanoma and metastases at early injection times. In this study, we developed radioiodine-labeled acetaminophen (I-AP) for specific, high-contrast imaging of malignant melanoma.
Methods
Radioiodine-125-labeled AP (125I–AP) was prepared using the chloramine-T method under no carrier-added conditions. Accumulation of radioactivity and the mechanism were evaluated in vitro using B16 melanoma cells incubated with 125I–AP or 14C(U)-labeled AP (14C–AP) with and without l-tyrosine as a substrate of tyrosinase, phenylthiourea as an inhibitor of tyrosinase, and thymidine as an inhibitor of DNA polymerase. The biological distribution of radioactivity in B16 melanoma-bearing mice was evaluated to determine the accumulation of 125I–AP. The stability of 125I–AP over time was evaluated in mice.
Results
The labeling efficiency and radiochemical purity of 125I–AP were >80% and 95%, respectively. Accumulation of 125I–AP was higher than that of 14C–AP at 60 min of incubation in vitro. The affinity of 14C–AP for tyrosinase and DNA polymerase was higher than that of 125I–AP, whereas the Vmax of 125I–AP was higher than that of 14C–AP. 125I–AP showed the highest accumulation in the gall bladder, and clearance from the blood and kidney was rapid. Melanoma:muscle and melanoma:normal skin ratios of 125I–AP for imaging contrast were the highest at 15 min after injection, whereas the melanoma:blood and melanoma:bone ratios gradually increased over time. 125I–AP remained stable for 60 min after injection in mice.
Conclusions
125I–AP has affinity for tyrosinase and high image contrast at early time points after injection. Therefore, 123I–AP imaging has great potential for specific, high-contrast detection of malignant melanoma.
Advances in Knowledge
123I–AP will provide specific, high-contrast imaging for malignant melanoma at early injection times.
Implications for patient care
123I–AP has good potential for the diagnosis of malignant melanoma compared with 123I–labeled 4-hydroxyphenylcysteamine, which we previously developed.
書誌情報 Nuclear Medicine and Biology

巻 59, p. 16-21, 発行日 2018-04
出版者
出版者 ELSEVIER
PubMed番号
識別子タイプ PMID
関連識別子 29413752
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nucmedbio.2017.12.008
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.nucmedbio.2017.12.008
関連名称 https://doi.org/10.1016/j.nucmedbio.2017.12.008
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:29.907908
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3