ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparative Studies with EPR and MRI on the In Vivo Tissue Redox Status Estimation using Redox-Sensitive Nitroxyl Probes: Influence of the Choice of the Region of Interest

https://repo.qst.go.jp/records/49033
https://repo.qst.go.jp/records/49033
2c1155e0-7527-4340-9c35-d200df39be91
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-06-13
タイトル
タイトル Comparative Studies with EPR and MRI on the In Vivo Tissue Redox Status Estimation using Redox-Sensitive Nitroxyl Probes: Influence of the Choice of the Region of Interest
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ken-ichiro, Matsumoto

× Ken-ichiro, Matsumoto

WEKO 1024734

Ken-ichiro, Matsumoto

Search repository
B. Mitchell, James

× B. Mitchell, James

WEKO 1024735

B. Mitchell, James

Search repository
C. Krishna, Murali

× C. Krishna, Murali

WEKO 1024736

C. Krishna, Murali

Search repository
Kenichiro, Matsumoto

× Kenichiro, Matsumoto

WEKO 1024737

en Kenichiro, Matsumoto

Search repository
抄録
内容記述タイプ Abstract
内容記述 In vivo decay rates of a nitroxyl contrast agent were estimated by a MR redox imaging (MRRI) technique and compared with the decay rates obtained by the electron paramagnetic resonance spectroscopy (EPRS) and imaging (EPRI). MRRI is a dynamic imaging technique employing T1-weighted pulse sequence, which can visualize a nitroxyl-induced enhancement of signal intensity by T1-weighted contrast. EPR techniques can directly measure the paramagnetic nitroxyl radical. Both the SCC tumor-bearing and normal legs of a female C3H mouse were scanned by T1-weighted SPGR sequence at 4.7 T with the nitroxyl radical, carbamoyl-PROXYL (CmP), as the contrast agent. Similarly, the time course of CmP in normal muscle and tumor tissues was obtained using an 700 MHz EPR spectrometer with a surface coil. The time course imaging of CmP was also performed by 300 MHz CW EPR imager. EPRS and EPRI gave slower decay rates of CmP compared to the MRRI. Relatively slow decay rate at peripheral region of the tumor tissues, which was found in the image obtained by MRRI, may contribute to the slower decay rates observed by EPRS and/or the EPRI measurements. To reliably determine the tissue redox status from the reduction rates of nitroxyls such as CmP, heterogenic structure in the tumor tissue must be considered. The high spatial and temporal resolution of T1-weighted MRI and the T1-enhancing capabilities of nitroxyls support the use of this method to map tissue redox status which can be a useful biomarker to guide appropriate treatments based on the tumor microenvironment.
書誌情報 Free Radical Research

巻 52, 号 2, p. 248-255, 発行日 2018-01
出版者
出版者 Taylor & Francis
ISSN
収録物識別子タイプ ISSN
収録物識別子 1029-2470
PubMed番号
識別子タイプ PMID
関連識別子 29320888
DOI
識別子タイプ DOI
関連識別子 10.1080/10715762.2018.1427235
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1080/10715762.2018.1427235
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:05:29.521973
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3