  1. 原著論文

A silicon strip detector array for energy verification and quality assurance in heavy ion therapy

https://repo.qst.go.jp/records/49023
https://repo.qst.go.jp/records/49023
b854843f-7b64-4a59-a070-c1a300081f95
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-17
タイトル
タイトル A silicon strip detector array for energy verification and quality assurance in heavy ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Emily, Debrot

× Emily, Debrot

WEKO 494418

Emily, Debrot

Search repository
Newall, Matthew

× Newall, Matthew

WEKO 494419

Newall, Matthew

Search repository
Guatelli, Susanna

× Guatelli, Susanna

WEKO 494420

Guatelli, Susanna

Search repository
Petasecca, Marco

× Petasecca, Marco

WEKO 494421

Petasecca, Marco

Search repository
松藤, 成弘

× 松藤, 成弘

WEKO 494422

松藤, 成弘

Search repository
Anatoly, Rozenfeld

× Anatoly, Rozenfeld

WEKO 494423

Anatoly, Rozenfeld

Search repository
Debrot Emily

× Debrot Emily

WEKO 494424

en Debrot Emily

Search repository
Newall Matthew

× Newall Matthew

WEKO 494425

en Newall Matthew

Search repository
Petasecca Marco

× Petasecca Marco

WEKO 494426

en Petasecca Marco

Search repository
松藤 成弘

× 松藤 成弘

WEKO 494427

en 松藤 成弘

Search repository
Anatoly Rozenfeld

× Anatoly Rozenfeld

WEKO 494428

en Anatoly Rozenfeld

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: The measurement of depth dose profiles for range and energy verification of heavy ionbeams is an important aspect of quality assurance procedures for heavy ion therapy facilities. Thesteep dose gradients in the Bragg peak region of these profiles require the use of detectors with highspatial resolution. The aim of this work is to characterize a one dimensional monolithic silicon detec-tor array called the “serial Dos e Magnifying Glass” (sDMG) as an independent ion beam energy andrange verificat ion system used for quality assurance conducted for ion beams used in heavy iontherapy.Methods: The sDMG detector consists of two linear arrays of 128 silicon sensitive volumes eachwith an effective size of 2mm 9 50lm 9 100lm fabricated on a p-type substrate at a pitch of200 lm along a single axis of detection. The detector was characterized for beam energy and rangeverification by measuring the response of the detector when irradiated with a 290 MeV/u12C ionbroad beam incident along the single axis of the detector embedded in a PMMA phanto m. Theenergy of the12C ion beam incident on the detector and the residual energy of an ion beam incidenton the phantom was determined from the measured Bragg peak position in the sDMG. Ad hoc MonteCarlo simulations of the experimental setup were also performed to give further insight into thedetector response.Results: The relative response profiles along the single axis measured with the sDMG detector werefound to have good agreement between experiment and simulation with the position of the Braggpeak determined to fall withi n 0.2 mm or 1.1% of the range in the detector for the two cases. Theenergy of the beam incident on the detector was found to vary less than 1% between experiment andsimulation. The beam energy incident on the phantom was determined to be (280.9  0.8) MeV/ufrom the experimental and (280.9  0.2) MeV/u from the simulated profiles. These values coincidewith the expected energy of 281 MeV/u.Conclusions: The sDMG detector response was studied experimentally and characterized using aMonte Carlo simulation. The sDMG detector was found to accurat ely determine the12C beam energyand is suited for fast energy and range verif ication quality assurance. It is proposed that the sDMG isalso applicable for verification of treatment planning systems that rely on particle range.
書誌情報 Medical Physics

巻 45, 号 2, p. 953-962, 発行日 2018-03
出版者
出版者 American Association of Physicists in Medicine
DOI
識別子タイプ DOI
関連識別子 10.1002/mp.12736
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:48.479077
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3