ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

High spatial resolution microdosimetry with monolithic ΔE-E detector on 12C beam: Monte Carlo simulations and experiment

https://repo.qst.go.jp/records/49021
https://repo.qst.go.jp/records/49021
f9adf041-1dd6-4986-ba2a-07d644ade120
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-17
タイトル
タイトル High spatial resolution microdosimetry with monolithic ΔE-E detector on 12C beam: Monte Carlo simulations and experiment
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tran, Thuy Linh

× Tran, Thuy Linh

WEKO 494374

Tran, Thuy Linh

Search repository
BOLST, David

× BOLST, David

WEKO 494375

BOLST, David

Search repository
SusannaGuatelli

× SusannaGuatelli

WEKO 494376

SusannaGuatelli

Search repository
Biasi, Giordano

× Biasi, Giordano

WEKO 494377

Biasi, Giordano

Search repository
Fazzi, Alberto

× Fazzi, Alberto

WEKO 494378

Fazzi, Alberto

Search repository
Sagia, Eleni

× Sagia, Eleni

WEKO 494379

Sagia, Eleni

Search repository
Prokopovich, Anthony

× Prokopovich, Anthony

WEKO 494380

Prokopovich, Anthony

Search repository
I.Reinhard, Mark

× I.Reinhard, Mark

WEKO 494381

I.Reinhard, Mark

Search repository
C., Keat Ying

× C., Keat Ying

WEKO 494382

C., Keat Ying

Search repository
Petasecca, Marco

× Petasecca, Marco

WEKO 494383

Petasecca, Marco

Search repository
L., F. Lerch Michael

× L., F. Lerch Michael

WEKO 494384

L., F. Lerch Michael

Search repository
Pola, Andrea

× Pola, Andrea

WEKO 494385

Pola, Andrea

Search repository
Agosteo, Stefano

× Agosteo, Stefano

WEKO 494386

Agosteo, Stefano

Search repository
松藤, 成弘

× 松藤, 成弘

WEKO 494387

松藤, 成弘

Search repository
Jackson, Michael

× Jackson, Michael

WEKO 494388

Jackson, Michael

Search repository
Anatoly, Rozenfeld

× Anatoly, Rozenfeld

WEKO 494389

Anatoly, Rozenfeld

Search repository
Tran Thuy Linh

× Tran Thuy Linh

WEKO 494390

en Tran Thuy Linh

Search repository
BOLST David

× BOLST David

WEKO 494391

en BOLST David

Search repository
Fazzi Alberto

× Fazzi Alberto

WEKO 494392

en Fazzi Alberto

Search repository
Sagia Eleni

× Sagia Eleni

WEKO 494393

en Sagia Eleni

Search repository
Prokopovich Anthony

× Prokopovich Anthony

WEKO 494394

en Prokopovich Anthony

Search repository
Petasecca Marco

× Petasecca Marco

WEKO 494395

en Petasecca Marco

Search repository
松藤 成弘

× 松藤 成弘

WEKO 494396

en 松藤 成弘

Search repository
Anatoly Rozenfeld

× Anatoly Rozenfeld

WEKO 494397

en Anatoly Rozenfeld

Search repository
抄録
内容記述タイプ Abstract
内容記述 Nuclear fragmentation produced in 12C ion therapeutic beams contributes significantly to the Relative Biological Effectiveness (RBE)—weighted dose in the distal edge of the Spread out Bragg Peak (SOBP) and surrounding tissues in out-of-field. Complex mixed radiation field originated by the therapeutic 12C ion beam in a phantom is difficult to measure. This study presents a new method to characterise the radiation field produced in a 12C ion beam using a monolithic E-E telescope which provides the capability to identify the particle components of the mixed radiation field as well as the microdosimetric spectra that allows derivation of the RBE based on a radiobiological model. The response of the monolithic E-E telescope to a 290 MeV/u 12C ion beam at defined positions along the pristine Bragg Peak was studied using the Geant4 Monte Carlo toolkit. The microdosimetric spectra derived from the E stage and the two-dimensional scatter plots of energy deposition in E and E stages of the device in coincidence are presented, as calculated in-field and out-of-field. Partial dose weighted contribution to the microdosimetric spectra from nuclear fragments and recoils, such as 1H, 4He, 3He, 7Li, 9Be and 11B, have been analysed for each position. Comparison of simulation and experimental results are presented and demonstrates that the microdosimetric spectra changes dramatically within 0.5 mm depth increments close to and at the distal edge of the Bragg Peak which is impossible to identify using conventional Tissue Equivalent Proportional Counter (TEPC).
書誌情報 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

巻 887, p. 70-80, 発行日 2018-01
出版者
出版者 Elsevier
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2017.12.079
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:50.047880
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3