  1. 原著論文

Validation of the Dose Distributions with Monte Carlo Simulation for Carbon Ion Cancer Therapy

https://repo.qst.go.jp/records/49012
https://repo.qst.go.jp/records/49012
2bcbdeb1-9dec-4689-adc3-479b2b0656f8
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-15
タイトル
タイトル Validation of the Dose Distributions with Monte Carlo Simulation for Carbon Ion Cancer Therapy
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ying, CK

× Ying, CK

WEKO 494256

Ying, CK

Search repository
Kamil, WA

× Kamil, WA

WEKO 494257

Kamil, WA

Search repository
松藤, 成弘

× 松藤, 成弘

WEKO 494258

松藤, 成弘

Search repository
松藤 成弘

× 松藤 成弘

WEKO 494259

en 松藤 成弘

Search repository
抄録
内容記述タイプ Abstract
内容記述 Charged particle therapy with carbon ions has advantages overconventional radiotherapy using x-raybeams.The application of charged particle therapy has rapidly increased overthelast decades. This is due to its characteristicBragg peak which has relatively low entrance doses and favourable doses distribution. In this research work, Geant4 based Monte Carlo simulation (MC) method has been used to calculate the radiation transportation and dose distributions in tissue-like media. The main objectiveof the workwasto compare the Geant4 simulated depth dose distributionswith experimental measurements and verifythe capability of the geant4 simulation toolkit. The carbon ion beams for the therapeutic energy of 350 MeV/u and 400 MeV/u respectively were simulated, with the same settingsas the experimental work carried out at the treatment room at Heavy Ion Medical Accelerator (HIMAC), National Institute of Radiological Sciences (NIRS), Chiba, Japan. The simulation results were verified with measurements data. The work was to measurethe accuracy and quality of the dose distributions by Geant4 MC methods. The results show that the Bragg peak and spread out Bragg peak (SOBP) distributions in simulation has fairly good agreement with measurements.
書誌情報 JOURNAL OF BIOMEDICAL AND CLINICAL SCIENCES

巻 2, 号 2, p. 1-7, 発行日 2018-03
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:55.748995
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3