ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development of bioassay system for evaluation of materials for personal protective equipment (PPE) against toxic effects of ionizing radiations.

https://repo.qst.go.jp/records/49000
https://repo.qst.go.jp/records/49000
6533dbe0-cbd9-4fdb-b24b-4cfd6bcfbb5d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-15
タイトル
タイトル Development of bioassay system for evaluation of materials for personal protective equipment (PPE) against toxic effects of ionizing radiations.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamauchi, Masatake

× Yamauchi, Masatake

WEKO 494124

Yamauchi, Masatake

Search repository
Sakuma, Sachiko

× Sakuma, Sachiko

WEKO 494125

Sakuma, Sachiko

Search repository
山内 正剛

× 山内 正剛

WEKO 494126

en 山内 正剛

Search repository
佐久間 三知子

× 佐久間 三知子

WEKO 494127

en 佐久間 三知子

Search repository
抄録
内容記述タイプ Abstract
内容記述 Health effects caused by ionizing radiations raise considerable concern among general public and radiation workers. To estimate ability of personal protective equipment (PPE) materials that reduce toxic effects of ionizing radiations, we developed an experimental bioassay system using Chinese Hamster V79 cells. The system developed here distinguished the biological effectiveness of X-ray that was significantly affected by elements composed of shielding materials. Survival of the cells exposed to sub-lethal dose of X-ray was enhanced more than 2 times when the X-ray was filtrated by a lead plate. Also filtration of the X-ray with a tungsten plate enhanced the cell survival more than three times. These results suggested the colony assay system developed here was useful for examination of the biological effectiveness of X-ray and the ability of PPE materials reducing the toxic effects caused by ionizing radiations.
書誌情報 Industrial Health

巻 55, 号 6, p. 580-583, 発行日 2017-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 0019-8366
PubMed番号
識別子タイプ PMID
関連識別子 29021414
DOI
識別子タイプ DOI
関連識別子 10.2486/indhealth.2017-0128
関連サイト
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/article/indhealth/55/6/55_2017-0128/_article
関連名称 https://www.jstage.jst.go.jp/article/indhealth/55/6/55_2017-0128/_article
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:22:04.701184
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3