WEKO3
アイテム
Performance of the HIMAC beam control system using multiple-energy synchrotron operation
https://repo.qst.go.jp/records/48997
https://repo.qst.go.jp/records/4899716ec8ec6-f679-41fd-896f-bda3e9088e2b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-05-15 | |||||
タイトル | ||||||
タイトル | Performance of the HIMAC beam control system using multiple-energy synchrotron operation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizushima, Kota
× Mizushima, Kota× Furukawa, Takuji× Iwata, Yoshiyuki× Hara, Yousuke× Saotome, Naoya× Saraya, Yuichi× Tansho, Ryohei× Sato, Shinji× Fujimoto, Tetsuya× Shirai, Toshiyuki× Noda, Koji× 水島 康太× 古川 卓司× 岩田 佳之× 原 洋介× 早乙女 直也× 皿谷 有一× 丹正 亮平× 佐藤 眞二× 白井 敏之× 野田 耕司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Multiple-energy synchrotron operation was developed to realize fast 3D scanning irradiation for carbon-ion radiotherapy. This type of operation can output various carbon-ion beams with different energies in a single synchrotron cycle. The beam control system used in this kind of operation was developed to quickly provide the beam energy and intensity required from the irradiation control system. The perfor-mance of the system was verified by experimental tests. The system could output beams of 197 different energies in 63 s. The beam intensity could be controlled for all the output beams without large ripples or overshooting. The experimental test of irradiation for prostate cancer treatment was also successfully performed, and the test results proved that our system can greatly reduce the irradiation time. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research B 巻 406, 号 A, p. 347-351, 発行日 2017-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nimb.2017.03.051 |